Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-23000035 Unavailable I/O Slot

ALM-23000035 Unavailable I/O Slot

Description

Alarm message:

For the %1 model, slot %2 of the I/O board (%3) is unavailable.
NOTE:

%1 example:

  • 9008V5-2P
  • 9008V5-4P
  • 9008V5-6P

%2 example:

  • 1
  • 2

%3 example:

  • REE BioBoard1
  • BIO Brd

Attribute

Alarm ID

Alarm Severity

Auto Clear

23000035

Minor

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The PCIe device in the slot cannot be used.

Possible Causes

A PCIe device is installed in an unavailable I/O slot.

Procedure

  1. Remove the PCIe device from the slot. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Contact Huawei technical support.