Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x06000005 RAID Controller Card Fault (RAID Controller Card, Major Alarm)

ALM-0x06000005 RAID Controller Card Fault (RAID Controller Card, Major Alarm)

Description

Alarm message:

arg2 RAID controller card arg1 failure. 

This alarm is generated when the RAID controller card is faulty.

Alarm object: RAID controller card

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x06000005

Major

Yes

Parameters

Name

Meaning

arg1

Slot number of the RAID controller card.

arg2

Front I/O module or compute node, for example, FIO or SCM.

Impact on the System

Services related to the RAID controller card are affected.

Possible Causes

The RAID controller card is faulty.

Procedure

  1. Restart the server and open the BIOS Device Manager in UEFI mode. On the Driver Health screen, select Repair the whole platform, and press Enter. Then, check whether the alarm is cleared.

    For details, see Troubleshooting > Platform Not healthy in HUAWEI V5 Server RAID Controller Card User Guide.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Remove and reinstall the RAID controller card. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Replace the RAID controller card and connect the power cable. After the server is powered on, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Getting Help.