Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0D000005 Failed to Read NIC Temperature (NIC, Minor Alarm)

ALM-0x0D000005 Failed to Read NIC Temperature (NIC, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the NIC arg1 temperature. 

This alarm is generated when the system failed to obtain the NIC temperature.

Alarm object: NIC

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0D000005

Minor

Yes

Parameters

Name

Meaning

arg1

Serial number of the NIC.

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.

Possible Causes

  • The iBMC is abnormal.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Remove the power cable to power off the server, and then reconnect the power cable to power on the server. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Getting Help.