Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0600001B Failed to Read the RAID Card BBU Temperature (RAID Controller Card, Minor Alarm)

ALM-0x0600001B Failed to Read the RAID Card BBU Temperature (RAID Controller Card, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the arg2 RAID controller card arg1 BBU temperature. 

This alarm is generated when the system failed to obtain the temperature of the battery backup unit (BBU) of the RAID controller card.

Alarm object: RAID controller card

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0600001B

Minor

Yes

Parameters

Name

Meaning

arg1

Slot number of the RAID controller card.

arg2

Front I/O module or compute node, for example, FIO or SCM.

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.

Possible Causes

  • The iBMC is faulty.
  • The BBU is faulty.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 2.

  2. Remove the power cable to power off the server, and then reconnect the power cable to power on the server. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 3.

  3. Replace the BBU. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 4.

  4. Getting Help.