Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-17000045 CMC Flash Memory Used Up

ALM-17000045 CMC Flash Memory Used Up

Description

Alarm message:

CMC flash memory used up.

Attribute

Alarm ID

Alarm Severity

Auto Clear

17000045

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

Services may become abnormal, and even the CMC cannot be loaded.

System Actions

None

Possible Causes

  • The upper threshold for the flash usage is set to a small value.
  • The available flash space is insufficient.

Procedure

  1. Check whether the value of Subject in alarm locating parameters is CMC1 or CMC2.

  2. Run the smmget -t flash capacity -d thresholdall command on the CLI of the faulty CMC, and check whether the upper threshold for major alarms is set correctly.

    The recommended threshold is 90.00.

    If the command output is as follows, the threshold is set properly:

    root@SMM:/# smmget -t flash capacity -d thresholdall 
    Upper Non-recoverable:  Not supported.  
    Upper Critical: 90.000 
    Upper Non-critical :  Not supported. 
    Lower Non-critical : Not supported.  
    Lower Critical       : Not supported.  
    Lower Non-recoverable: Not supported.     

  3. Run the smmset -t flash capacity -d uppercritical -v value command (value indicates the upper threshold for major alarms) on the CMC CLI to change the threshold. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Run the reboot command on the CMC CLI to restart the CMC. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 5.

  5. Replace the CMC. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 6.

  6. Contact Huawei technical support.

Clearing

This alarm is cleared when the sensor detects that the flash usage is lower than the upper threshold for major alarms.

After the fault is rectified, the system automatically clears the alarm.