KunLun 9008 V5 Alarm Handling 05

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x28000017 Incorrect Power Cable Connection (Cable, Major Alarm)

ALM-0x28000017 Incorrect Power Cable Connection (Cable, Major Alarm)

Description

Alarm message:

Power cable [arg2] of the [arg1] is connected incorrectly. 

This alarm is generated when the power cable is not connected correctly.

Alarm object: cable

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x28000017

Major

Yes

Parameters

Name

Meaning

arg1

Component connected with the cable, for example, disk backplane or fan backplane.

arg2

Silkscreen on the power cable port, for example, POWER1 or POWER2.

Impact on the System

The power supply is affected.

Possible Causes

  • The power cable is not connected properly.
  • The power cable is faulty.
  • The component connected to the power cable is faulty.

Procedure

  1. Check whether the power cable is connected correctly.

    • If yes, go to step 3.
    • If no, go to step 2.

  2. Connect the power cables in correct sequence. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 3.

  3. Remove and reconnect the power cables. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 4.

  4. Replace the power cables. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 5.

  5. Replace the component to which the power cable is connected. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 6.

  6. Getting Help.