KunLun 9008 V5 Alarm Handling 05

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x12000017 Failed to Read Outlet Temperature (Chassis, Minor Alarm)

ALM-0x12000017 Failed to Read Outlet Temperature (Chassis, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the air outlet arg1 temperature. 

This alarm is generated when the system failed to obtain the outlet temperature.

Alarm object: chassis

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x12000017

Minor

Yes

Parameters

Name

Meaning

arg1

Serial number of the outlet.

Impact on the System

The temperature at the air outlet cannot be monitored, and the fan speed adjustment is affected.

Possible Causes

  • The iBMC is faulty.
  • The component holding the outlet sensor is faulty.

Procedure

  1. Log in to the iBMC WebUI or CLI.

    For details, see the iBMC user guide of the server you use.

  2. Restart the iBMC.

    • On the WebUI, choose System > Firmware Upgrade and click Restart iBMC.
    • On the CLI, run the ipmcset -d reset command.

  3. After the iBMC restarts, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 4.

  4. Power off the server, remove and reconnect the power cables, and power on the server. Check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 5.

  5. Replace the component hosting the outlet sensor. Then, check whether the alarm is cleared.

    For details see "Replacing Parts" in the user guide.

    The air outlet temperature sensor of the rack server is on the mainboard.

    • If yes, no further action is required.
    • If no, go to step 6.

  6. Getting Help.