Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x100000A9 Mainboard Fault (Mainboard, Major Alarm)

ALM-0x100000A9 Mainboard Fault (Mainboard, Major Alarm)

Description

Alarm message:

Mainboard arg1 clock arg2 signals lost.

This alarm is generated when the mainboard clock circuit is faulty.

Alarm object: mainboard

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x100000A9

Major

Yes

Parameters

Name

Meaning

arg1

Type of the mainboard clock. For example, 100MHz or 156.25MHz.

arg2

Mainboard clock number.

Impact on the System

The system operation is affected.

Possible Causes

The mainboard is faulty.

Procedure

  1. Replace the mainboard. After the server is powered on, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 2.

  2. Getting Help.