Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-23000029 Failed to Obtain the ID of an I/O Module

ALM-23000029 Failed to Obtain the ID of an I/O Module

Description

Alarm message:

Failed to obtain data of the board id for (%1).
NOTE:

%1 value example: BIO1 to BIOn

Attribute

Alarm ID

Alarm Severity

Auto Clear

23000029

Critical

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The CMC cannot manage the I/O module.

System Actions

None.

Possible Causes

  • The CPLD of the I/O module is abnormal.

Procedure

  1. Replace the I/O module. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Contact Huawei technical support.