Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x23000013 Failed to Read I/O Board 12 V Voltage (I/O Board, Minor Alarm)

ALM-0x23000013 Failed to Read I/O Board 12 V Voltage (I/O Board, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the 12 V voltage for I/O board(arg1). 

This alarm is generated when the system failed to obtain the voltage of the 12 V detection point of the I/O board.

Alarm object: I/O board

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x23000013

Minor

No

Parameters

Name

Meaning

arg1

Location of the I/O board:

  • BIO
  • FIO

Impact on the System

The voltage cannot be monitored. No alarm will be reported when the voltage is not in the normal range.

Possible Causes

The iBMC does not work normally.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Remove and reinstall the power cable or board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Getting Help.