Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Alarm Thresholds for other TE Resource

Configuring Alarm Thresholds for other TE Resource

Conditions that trigger TE resource threshold-reaching alarms can be configured. If the number of Auto bypass tunnel interfaces, or the number of Auto Primary Tunnels reaches the upper alarm threshold, the device can report an alarm, which facilitates operation and maintenance.

Procedure

  1. Run:

    system-view

    The system view displayed.

  2. Run:

    mpls

    The MPLS view is displayed.

  3. Run one or more of the following commands:
    • Run:

      mpls autobypass-tunnel-number threshold-alarm upper-limit upper-limit-value lower-limit lower-limit-value

      The conditions that trigger the threshold-reaching alarm and its clear alarm for Auto bypass tunnel interfaces are configured.

    • Run:

      mpls autoprimary-tunnel-number threshold-alarm upper-limit upper-limit-value lower-limit lower-limit-value

      The conditions that trigger the threshold-reaching alarm and its clear alarm for Auto Primary Tunnels are configured.

    Note the following issues when configuring trigger conditions:

    • upper-limit-value: upper alarm threshold for the proportion of used TE resources to all TE resources supported by a device.
    • lower-limit-value: lower alarm threshold for the proportion of used TE resources to all TE resources supported by a device.
    • The upper alarm threshold must be greater than the lower alarm threshold.
    NOTE:
    • Each command only configures the trigger conditions for an alarm and its clear alarm. Although trigger conditions are met, the alarm and its clear alarm can be generated only after the snmp-agent trap enable feature-name mpls_lspm trap-name { hwmplsresourcethresholdexceed | hwmplsresourcethresholdexceedclear } command is run to enable the device to generate an MPLS resource insufficiency alarm and its clear alarm.

    • After the snmp-agent trap enable feature-name mpls_lspm trap-name { hwmplsresourcetotalcountexceed | hwmplsresourcetotalcountexceedclear } command is run to enable the device to generate limit-reaching alarms and their clear alarms, the following situations occur:

      • If the number of used TE resources reaches the maximum number of TE resources supported by a device, a limit-reaching alarm is generated.

      • If the number of used TE resources falls below 95% of the maximum number of TE resources supported by a device, a clear alarm is generated.

  4. Run:

    commit

    The configuration is committed.