Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Configurations

Checking the Configurations

After configuring a static bidirectional co-routed LSP, you can view its status.

Prerequisites

A static bidirectional co-routed LSP has been established.

Procedure

  • Run the display mpls te bidirectional static-cr-lsp [ lsp-name ] [ verbose ] command to check the specified static bidirectional co-routed LSP.

Example

Run the display mpls te bidirectional command to view information about the specified static bidirectional co-routed LSP.
<HUAWEI> display mpls te bidirectional static-cr-lsp
TOTAL          : 2     STATIC CRLSP(S)
UP             : 2     STATIC CRLSP(S)
DOWN           : 0     STATIC CRLSP(S)
Name                FEC                I/O Label    I/O If                Status
Tunnel10         3.3.3.3/32         NULL/20      -/GE1/0/6            
                                       20/NULL      GE/1/6/-              Up
Tunnel11         3.3.3.3/32         NULL/21      -/GE1/0/1            
                                       21/NULL      GE1/0/1/-             Up