No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

NE40E V800R010C00 Configuration Guide - MPLS 01

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Configuring a Best-effort Path

(Optional) Configuring a Best-effort Path

A best-effort path is configured to take over traffic if both the primary and backup CR-LSPs fail.

Context

In hot-standby mode, perform the following steps on the ingress of a TE tunnel:

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    interface tunnel tunnel-number

    The view of the MPLS TE tunnel interface is displayed.

  3. Run:

    mpls te backup ordinary best-effort

    A best-effort path is configured.

  4. (Optional) Run:

    mpls te affinity property properties [ mask mask-value ] best-effort

    The affinity property of the best-effort path is configured.

  5. (Optional) Run:

    mpls te hop-limit hop-limit-value best-effort

    The hop limit is set for the best-effort path.

  6. Run:

    commit

    The configuration is committed.