Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Setting the Value of the igp-sync-delay Timer

(Optional) Setting the Value of the igp-sync-delay Timer

When an LDP session is reestablished on a faulty link, LDP starts the igp-sync-delay timer to wait for the establishment of an LSP. After the igp-sync-delay timer expires, LDP-IGP synchronization is complete.

Procedure

  • Perform the following steps:
    1. Run:

      system-view

      The system view is displayed.

    2. Run:

      mpls ldp

      The MPLS-LDP view is displayed.

    3. Run:

      igp-sync-delay timer value

      The igp-sync-delay timer value is set.

    4. Run:

      commit

      The configurations are committed.

  • Perform the following steps:
    1. Run:

      system-view

      The system view is displayed.

    2. Run:

      interface interface-type interface-number

      The interface view is displayed.

    3. Run:

      mpls ldp timer igp-sync-delay value

      The igp-sync-delay timer value is set.

    4. Run:

      commit

      The configurations are committed.