Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Creating Remote LDP Peers on Both Ends of a TE Tunnel

Creating Remote LDP Peers on Both Ends of a TE Tunnel

Configure nodes on both ends of a TE tunnel as remote LDP peers.

Context

If the destination address of the TE tunnel is not the LSR ID of the egress, the interface with the destination address must be enabled with LDP.

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    mpls ldp remote-peer remote-peer-name

    The remote MPLS LDP peer view is displayed.

  3. Run:

    remote-ip ip-address

    An IP address is assigned to the remote LDP peer.

  4. Run:

    commit

    The configurations are committed.