Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Grounding Methods to Prevent Electrostatic Discharge

Grounding Methods to Prevent Electrostatic Discharge

Use one or more of the following grounding methods when handling or installing electrostatic-sensitive components:

  • Use a wrist strap that connects to a grounded workplace or server chassis. The wrist strap must be elastic and the resistance must be at least one ohm (±10%). To provide proper grounding, wear the strap snug against the skin.
  • Use heel straps, toe straps, or boot straps in standing workplaces. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.
  • Use conductive field service tools.
  • Use a portable field service kit with a folding static-dissipating work mat.