Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Sensor Test Command (sensor -d test)

Sensor Test Command (sensor -d test)

Function

The sensor -d test command is used to simulate the sensor status or value.

Format

ipmcset -t sensor -d test -v <sensorname/stopall> [value/stop]

Parameters

Parameter Description Value
sensorname/stopall Specifies the sensor name.
  • sensorname: specifies the sensor name.
  • stopall: Stops all tests.
value/stop Specifies the analog value.
  • value: specifies the analog value of the sensor test.
  • stop: Stops all tests.

Usage Guidelines

  • If the iBMC version is earlier than V253, running this command will simulate the related alarm.
  • If the iBMC version is V253 or later, running this command will not simulate the related alarm.
  • If the iBMC version is V290 or later, run the ipmcset -t precisealarm -d mock command to simulate alarms.

Example

# Simulate a CPU1 Core Rem sensor temperature value of 100°C.

iBMC:/->ipmcset -t sensor -d test -v "CPU1 Core Rem" 100
Sensor test successfully.