Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Querying System Health Event Information (healthevents)

Querying System Health Event Information (healthevents)

Function

The healthevents command is used to query the health event information about the system.

Format

ipmcget [-t fru0] -d healthevents

Parameters

None

Usage Guidelines

None

Example

# Query health event information about the system.

iBMC:/->ipmcget -d healthevents
Event Num  | Event Time           | Alarm Level  | Event Code   | Event Description
1          | 2016-10-17 06:27:14  | Minor        | 0x01000021   | Failed to obtain data of the CPU 1 DIMM VDDQ2 voltage.
2          | 2016-10-17 10:24:43  | Critical     | 0x01000015   |  DIMM020 DIMM  configuration error or training failed.
3          | 2016-10-17 10:24:43  | Major        | 0x01000017   |  DIMM012 DIMM  triggered an uncorrectable error, .
4          | 2016-10-17 10:24:43  | Critical     | 0x01000015   |  DIMM001 DIMM  configuration error or training failed.
5          | 2016-10-17 08:47:27  | Major        | 0x03000009   | [Mock]PSU 1 failure.
6          | 2016-10-17 07:40:57  | Minor        | 0x0D000003   | The NIC 1 temperature (150 degrees C) exceeds the overtemperature threshold (100 degrees C).
7          | 2016-10-17 07:04:47  | Major        | 0x2100000B   | Data rebuild failed at SD card 2.
8          | 2016-10-17 06:33:21  | Major        | 0x2C000029   | The OS is forcibly powered off and on due to the watchdog timeout.