Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuration File Description

Configuration File Description

Table 9-1, Table 9-2, and Table 9-3 describe the parameters in iBMC, BIOS, and RAID controller card configuration files.

To ensure data security, some of the iBMC and RAID controller configuration in the configuration file imported after the mainboard replacement do not take effect.

Table 9-1  iBMC parameters
Type Exported Parameter Exported Subparameter Description Imported by Configuration File
Local user User UserName Specifies the name of a user. Supported
User PassWord Specifies the password of a user. Not supported

Sensitive information is displayed in ciphertext in the configuration file.

User Privilege Specifies the rights of a user. Supported
User UserRoleId Specifies the role of a user. Supported
User PermitRuleIds Specifies the login rules for a user. Supported
User LoginInterface Specifies the login interface for a user. Supported
User IsUserEnable Specifies whether the user is enabled. Not supported

The value is displayed in the configuration file.

User IsUserLocked Specifies whether the user is locked. Not supported

The value is displayed in the configuration file.

UserRole KVMMgnt Specifies the KVM rights. Supported
UserRole UserMgnt Specifies the user management rights. Supported
UserRole VMMMgnt Specifies the VMM rights. Supported
UserRole BasicSetting Specifies the rights for performing basic settings. Supported
UserRole ReadOnly Specifies the read-only rights. Supported
UserRole PowerMgnt Specifies the power control rights. Supported
UserRole DiagnoseMgnt Specifies the debugging and diagnosis rights. Supported
UserRole ConfigureSelf Specifies the rights for configuring the user's own data. Supported
UserRole SecurityMgnt Specifies the security configuration rights. Supported
Two-factor authentication MutualAuthentication MutualAuthenticationState Specifies whether two-factor authentication is enabled. Supported
MutualAuthentication MutualAuthenticationOCSP Specifies whether the two-factor authentication revocation check is enabled. Supported
LDAP configuration LDAP Enable Specifies whether LDAP is enabled. Supported
LDAP CertStatus Specifies whether LDAP certificate verification is enabled. Supported
LDAP HostAddr Specifies the LDAP server address. Supported
LDAP Port Specifies the LDAPS port number. Supported
LDAP UserDomain Specifies the domain name. Supported
LDAP Folder Specifies the folder for which user applications are stored. Supported
LDAP BindDN Specifies the distinguished name of an LDAP proxy user. Supported
LDAP BindDNPsw Specifies the password of the LDAP proxy user. Not supported

The value is displayed in the configuration file.

LDAPServer Enable Specifies whether LDAP is enabled. Supported
LDAPServer CertStatus Specifies whether LDAP certificate verification is enabled. Supported
LDAPServer HostAddr Specifies the LDAP server address. Supported
LDAPServer Port Specifies the LDAPS port number. Supported
LDAPServer UserDomain Specifies the domain name. Supported
LDAPServer Folder Specifies the user application folder. Supported
LDAPServer BindDN Specifies the distinguished name of an LDAP proxy user. Supported
LDAPServer BindDNPsw Specifies the user password. Not supported

The value is displayed in the configuration file.

LDAPGroup GroupName Specifies the LDAP group name. Supported
LDAPGroup GroupFolder Specifies the application folder for an LDAP group. Supported
LDAPGroup GroupPermitRuleIds Specifies the login rules for an LDAP group. Supported
LDAPGroup GroupLoginInterface Specifies the login interface for an LDAP group. Supported
LDAPGroup GroupPrivilege Specifies the rights of an LDAP group. Supported
Security hardening PasswdSetting EnableStrongPassword Specifies whether password complexity check is enabled. Supported
SecurityEnhance SSHPasswordAuthentication Specifies whether SSH password authentication is enabled. Supported
SecurityEnhance UserInactTimeLimit Specifies the time limit for which a user is inactive. Supported
SecurityEnhance PwdExpiredTime Specifies the validity period of a password. Supported
SecurityEnhance MinimumPwdAge Specifies the minimum validity period of a password. Supported
SecurityEnhance InitialPwdPrompt Specifies whether to enable the function of prompting the user to change the password. Supported
SecurityEnhance ExcludeUser Specifies the user who can log in to the system in emergencies. Supported
SecurityEnhance OldPwdCount Specifies the previous password that cannot be used. Supported
SecurityEnhance AuthFailMax Specifies the maximum number of failed login attempts allowed before a user account is locked. Supported
SecurityEnhance AuthFailLockTime Specifies the user lockout period. Supported
PermitRule TimeRuleInfo Specifies the rules for time-based logins. Supported
PermitRule IpRuleInfo Specifies the rules for IP-based logins. Supported
PermitRule MacRuleInfo Specifies the rules for MAC-based logins. Supported
SecurityEnhance PermitRuleIds Specifies whether rules are enabled. Supported
SecurityEnhance BannerState Specifies whether login security information configuration is enabled. Supported
SecurityEnhance BannerContent Provides the login security information. Supported
Network configuration BMC HostName Specifies the iBMC host name. Not supported

The value is displayed in the configuration file.

EthGroup NetMode Specifies the network port mode. Supported
EthGroup ActivePort Specifies the management network port. Supported
EthGroup IpVersion Specifies whether IP is enabled. Supported
EthGroup IpMode Specifies how IPv4 addresses are assigned. Supported
EthGroup IpAddr Specifies an IPv4 address. Not supported

The value is displayed in the configuration file.

EthGroup SubnetMask Specifies an IPv4 subnet mask. Not supported

The value is displayed in the configuration file.

EthGroup DefaultGateway Specifies the default IPv4 gateway IP address. Not supported

The value is displayed in the configuration file.

EthGroup Ipv6Mode Specifies how IPv6 addresses are allocated. Supported
EthGroup Ipv6Addr Specifies an IPv6 address. Not supported

The value is displayed in the configuration file.

EthGroup Ipv6Prefix Specifies the prefix length of an IPv6 address. Not supported

The value is displayed in the configuration file.

EthGroup Ipv6DefaultGateway Specifies the default IPv6 gateway IP address. Not supported

The value is displayed in the configuration file.

DNSSetting IPVer Specifies the IP version bound with the DNS. Supported
DNSSetting Mode Specifies how the DNS addresses are assigned. Supported
DNSSetting PrimaryDomain Specifies the preferred DNS server. Supported
DNSSetting BackupDomain Specifies the alternate DNS server. Supported
DNSSetting DomainName Specifies the DNS domain name. Supported
EthGroup VlanState Specifies whether VLAN is enabled. Supported
EthGroup VlanID Specifies the VLAN ID. Supported
NTP EnableStatus Specifies whether NTP is enabled. Supported
NTP Mode Specifies the NTP mode. Supported
NTP PreferredServer Specifies the address of the preferred NTP server. Supported
NTP AlternativeServer Specifies the address of the alternate NTP server. Supported
NTP AuthEnableStatus Specifies whether NTP server authentication is enabled. Supported
NTP MinPollInterval Specifies the minimum NTP synchronization interval. Supported
NTP MaxPollInterval Specifies the maximum NTP synchronization interval. Supported
VNC EnableState Specifies whether VNC is enabled. Supported
VNC Password Specifies the VNC password. Not supported

Sensitive information is displayed in ciphertext in the configuration file.

VNC Timeout Specifies the validity period of the VNC password. Supported
VNC SSLEnableState Specifies whether the SSL is enabled. Supported
VNC Port Specifies the VNC service port number. Supported
VNC KeyboardLayout Specifies the keyboard layout. Supported
VNC PermitRuleIds Specifies the login rules. Supported
BMC TimeZoneStr Specifies the time zone. Supported
Service configuration SSH State Specifies whether SSH is enabled. Supported
SSH Port Specifies the SSH port number. Supported
Snmp State Specifies whether SNMP Agent is enabled. Supported
Snmp PortID Specifies the SNMP Agent. Supported
Kvm State Specifies whether KVM is enabled. Supported
Kvm Port Specifies the KVM port number. Supported
Vmm State Specifies whether VMM is enabled. Supported
Vmm Port Specifies the VMM port number. Supported
Video State Specifies whether Video is enabled. Supported
Video Port Specifies the Video port number. Supported
WEBHTTP State Specifies whether HTTP is enabled. Supported
WEBHTTP Port Specifies the HTTP port number. Supported
WEBHTTPS State Specifies whether HTTPS is enabled. Supported
WEBHTTPS Port Specifies the HTTPS port number. Supported
RmcpConfig LanState Specifies whether IPMI LAN (RMCP) is enabled. Supported
RmcpConfig Port1 Specifies the IPMI LAN (RMCP) port 1. Supported
RmcpConfig Port2 Specifies the IPMI LAN (RMCP) port 2. Supported
RmcpConfig LanPlusState Specifies whether IPMI LAN (RMCP+) is enabled. Supported
System configuration Snmp V1State Specifies whether SNMPv1 is supported. Supported
Snmp V2CState Specifies whether SNMPv2c is supported. Supported
Snmp LongPasswordEnable Specifies whether long passwords are enabled. Supported
Snmp ROCommunity Specifies the read-only community string. Not supported

Sensitive information is displayed in ciphertext in the configuration file.

Snmp RWCommunity Specifies the read-write community string. Not supported

Sensitive information is displayed in ciphertext in the configuration file.

Snmp RWCommunityState Specifies whether the read/write community name is enabled. Supported
Snmp SNMPV1V2CPermitRuleIds Specifies the SNMP login rules. Supported
Snmp AuthProtocol Specifies the SNMPv3 authentication algorithm. Supported
Snmp PrivProtocol Specifies the SNMPv3 encryption algorithm. Supported
SecurityEnhance TLSVersion Specifies the TLS version. Supported
SecurityEnhance EnableUserMgnt Specifies whether user management on the service side is enabled. Supported
Session Timeout Specifies the timeout period for a web session. Supported
Session Mode Specifies the web session mode. Supported
BMC LocationInfo Specifies the equipment location. Not supported

The value is displayed in the configuration file.

MeInfo CpuUtiliseThre Specifies the CPU usage alarm threshold. Supported
MeInfo MemUtiliseThre Specifies the memory usage alarm threshold. Supported
MeInfo DiskPartitionUsageThre Specifies the hard disk partition usage alarm threshold. Supported
PRODUCT WOLState Specifies whether the wake on LAN function is enabled. Supported
System boot option Bios StartOption Specifies the first boot device. Supported
Bios StartOptionFlag Specifies whether the boot setting takes effect permanently or just for one time only. Supported
Bios StartOptionFlagExt Specifies whether the previous setting has taken effect when the effective mode is One time. Supported
Alarm settings SyslogConfig EnableState Specifies whether Syslog is enabled. Supported
SyslogConfig MsgIdentity Identifies the Syslog host. Supported
SyslogConfig MsgSeverity Specifies Syslog alarm severity level. Supported
SyslogConfig NetProtocol Specifies the Syslog transmission protocol. Supported
SyslogConfig AuthType Specifies the Syslog authentication mode. Supported
SyslogItemCfg EnableState Specifies whether the Syslog server is enabled. Supported
SyslogItemCfg DestAddr Specifies the Syslog server address. Supported
SyslogItemCfg DestPort Specifies the Syslog server port number. Supported
SyslogItemCfg LogSrcMask Specifies the Syslog log type. Supported
TrapConfig TrapEnable Specifies whether Trap is enabled. Supported
TrapConfig TrapVersion Specifies the Trap version. Supported
TrapConfig Trapv3Userid Specifies the SNMPv3 user name. Supported
TrapConfig TrapMode Specifies Trap mode. Supported
TrapConfig TrapIdentity Identifies the Trap host. Supported
TrapConfig CommunityName Specifies the Trap community name. Not supported

Sensitive information is displayed in ciphertext in the configuration file.

TrapConfig SendSeverity Specifies the severity level for sending a Trap alarm. Supported
TrapItemCfg ItemEnable Specifies whether the Trap server is enabled. Supported
TrapItemCfg DestIpAddr Specifies the Trap server address. Supported
TrapItemCfg DestIpPort Specifies the Trap server port number. Supported
TrapItemCfg Separator Specifies the delimiter to be used in a message. Supported
TrapItemCfg Time Specifies the message content (time). Supported
TrapItemCfg SensorName Specifies the message content (sensor name). Supported
TrapItemCfg Severity Specifies the message content (severity level). Supported
TrapItemCfg EventCode Specifies the message content (event code). Supported
TrapItemCfg EventDesc Specifies the message content (event description). Supported
TrapItemCfg ShowKeyWord Specifies whether to display the keywords in a message. Supported
TrapItemCfg BobEnable Specifies whether trap messages can be transferred through inband channels. Supported
TrapItemCfg BmaVethIpAddr Specifies the IP address of the BMA veth port for transferring trap messages through the inband channels. Supported
TrapItemCfg BmaVethIpPort Specifies the number of the BMA veth port for transferring trap messages through the inband channels. Supported
SmtpConfig SmtpEnable Specifies whether SMTP is enabled. Supported
SmtpConfig SmtpServer Specifies the SMTP address. Supported
SmtpConfig TlsSendMode Specifies whether TLS is enabled. Supported
SmtpConfig AnonymousMode Specifies whether anonymous login is enabled. Supported
SmtpConfig LoginName Specifies the email sender name. Supported
SmtpConfig LoginPasswd Specifies the email sender password. Not supported

Sensitive information is displayed in ciphertext in the configuration file.

SmtpConfig SenderName Specifies the mailbox address of the sender. Supported
SmtpConfig TempletTopic Specifies the email subject. Supported
SmtpConfig TempletIpaddr Specifies whether the email subject contains the host name. Supported
SmtpConfig TempletBoardSn Specifies whether the email subject contains the board serial number. Supported
SmtpConfig TempletAsset Specifies whether the email subject contains the product asset tag. Supported
SmtpConfig SendSeverity Specifies the severity levels of the alarms to be sent. Supported
SmtpItemCfg EmailName Specifies the recipient address. Supported
SmtpItemCfg EmailDesc Provides information about the alarm Supported
SmtpItemCfg ItemEnable Specifies whether alarm email notifications are sent to the recipient. Supported
Power control ChassisPayload PowerOffTimeoutEN Specifies whether power-off timeout period is enabled. Supported
ChassisPayload PowerOffTimeout Specifies the power-off timeout period. Supported
ChassisPayload PwrButtonLock Specifies whether the power button on the server front panel is disabled. Supported
ChassisPayload PowerRestorePolicy Specifies the power restore policy when the power supply is connected. Supported
Power PowerCapping Enable Specifies whether power capping is enabled. Supported
PowerCapping LimitValue Specifies the power cap value. Supported
PowerCapping FailAction Specifies whether to forcibly shut down the server if the power capping fails. Supported
Energy saving settings SysPower ExpectedMode Specifies the power supply working mode. Supported
SysPower ExpectedActive Specifies the active power supply. Supported
Remote control Kvm EncryptState Specifies whether KVM encryption is enabled. Supported
Vmm EncryptState Specifies whether VMM encryption is enabled. Supported
Kvm KeyboardMode Specifies whether persistent connection of the virtual keyboard and mouse is enabled. Supported
Kvm KvmTimeout Specifies the remote console timeout period. Supported
Kvm LocalKVMState Specifies whether local KVM is enabled. Supported
Video playback Video VideoSwitch Specifies whether video recording is enabled. Supported
Screenshot Kvm ScreenSwitch Specifies whether last screenshot is enabled. Supported
Black box Diagnose BlackBoxState Specifies whether black box is enabled. Supported
Serial port data Diagnose SolDataState Specifies whether serial port data is enabled. Supported
Others HMMSSHNAT State Specifies whether NAT is enabled. Supported
ExPortConfig State Specifies whether SSDP is enabled. Supported
HMMSSHNAT Port Specifies the NAT port number. Supported
Bios BiosPrintFlag Specifies the setting of the BIOS print switch. Supported
Cooling Mode Specifies the speed adjustment mode of fans. Not supported

The value is displayed in the configuration file.

Cooling PowerMode Specifies the power supply mode. Supported
Cooling Level Specifies the fan speed level. Not supported

The value is displayed in the configuration file.

Stateless Enable Specifies whether stateless computing is enabled. Supported
Stateless SysManagerID Specifies the remote management ID. (stateless computing configuration) Supported
Stateless AutoPowerOn Specifies whether to enable self-control power-on. (stateless computing configuration) Supported
Stateless BroadcastNetSegment Specifies the broadcast network segment used for automatic discovery. (stateless computing configuration) Supported
Stateless BroadcastPort Specifies the broadcast port number used for automatic discovery. (stateless computing configuration) Supported
Stateless SysManagerIP Specifies the IP address of the server that performs power control. (stateless computing configuration) Supported
Stateless SysManagerPort Specifies the port number of the server that performs power control. (stateless computing configuration) Supported
USBMassStorage UmsMaxUpdateSpace Specifies the flag indicating that the component configuration or upgrade package is delivered to the NAND flash memory. Supported
USBMassStorage SpConfigFileReady Specifies the mode for accessing the SP. Supported
USBMassStorage SPStartmode Specifies the interval between the SP operation completion time and the OS reset time. Supported
USBMassStorage SysRestartDelay Specifies the OS restart delay. Supported
SmBios Version Specifies the value of the Version parameter in SMBIOS. Supported
SmBios SKUNumber Specifies the value of the SKUNumber parameter in SMBIOS. Supported
SmBios Family Specifies the value of the Family parameter in SMBIOS. Supported
Table 9-2  BIOS parameters
Parameter Description
ProcessorHyperThreadingDisable Specifies whether processor hyper-threading is enabled.
ProcessorFlexibleRatioOverrideEnable Specifies whether the feature of setting the CPU frequency upper limit is enabled. This feature is disabled by default.
ProcessorFlexibleRatio Specifies the CPU frequency upper limit. By default, it is the nominal CPU frequency.
MonitorMwaitEnable Specifies whether Monitor/Mwait is enabled.
ProcessorVmxEnable Specifies whether CPU virtualization is enabled.
ProcessorLtsxEnable Specifies whether Intel TXT is enabled.
MlcStreamerPrefetcherEnable Specifies whether hardware prefetcher is enabled. Before processing instructions or data, the CPU prefetches these instructions or data and saves them to the L2 cache. This reduces memory read time, eliminates potential bottlenecks, and therefore improves system performance.
MlcSpatialPrefetcherEnable Specifies whether adjacent cache prefetcher is enabled. This feature allows prefetch of the data adjacent to the data to be read. This improves read speed significantly.
DCUStreamerPrefetcherEnable Specifies whether DCU streamer prefetcher is enabled. This function allows CPU data to be prefetched, which reduces data read time.
DCUIPPrefetcherEnable Specifies whether DCU IP prefetcher is enabled. This function enables the system to check historical records for the data that must be prefetched, which reduces data read time.
CustomPowerPolicy Menu for selecting the energy-saving mode. It does not support customization.
PowerSaving Indicates a Huawei-customized parameter for Dynamic Energy Management Technology (DEMT), integrates uniBIOS frequency adjustment algorithms developed by Huawei, and improves energy efficiency test results. This parameter is valid only for specific OSs
ProcessorEistEnable Specifies whether Enhanced Intel SpeedStep® Technology (EIST) is enabled. EIST enables CPU frequency to be dynamically adjusted based on workloads, reducing heat dissipation.
TurboMode Specifies whether CPU Turbo mode is enabled.
PStateDomain PStateDomain switch. PStateDomain adjusts frequencies by core or package.
ProcessorCcxEnable CPU C-state control menu, which controls the power consumption of CPUs in idle state.
TStateEnable CPU T-state switch. This function is not available because it limits the CPU frequency.
PackageCState Package C state setting.
C3Enable CPU C3 state setting switch.
C6Enable CPU C6 state setting switch.
ProcessorC1eEnable CPU C1e state setting switch.
OSCx ACPI C2/C3 adjustment
QpiLinkSpeed QPI LINK Speed
ClusterOnDieEn Memory Snoop mode ClusterOnDie setting switch
EarlySnoopEn Memory Snoop mode EarlySnoop and HomeSnoop setting switch
DdrFreqLimit Memory frequency setting switch.
RankMargin Rank Margin Tool switch.
rmtPatternLength RMT Pattern Length, which is set when Rank Margin Tool is enabled.
MemTestOnFastBoot Memory test switch set for fast boot.
ADREn Memory ADR switch
CustomRefreshRateEn Memory refresh rate switch.
CustomRefreshRate Specifies the memory refresh rate.
refreshMode Specifies the memory refresh mode. 1 indicates 2x memory self-refresh, and 0 indicates that 2x memory self-refresh is not supported. If this parameter is set to 1, the memory refresh rate will be doubled when the memory DIMM exceeds 85ºC.
mcODTOverride Memory mc on die termination (ODT) setting. ODT(on die termination) is a mechanism that allows the DRAM controller to dynamically control the termination resistance value of DQ/DQS/DM pins on DRAM devices in a variety of ways. The value can be 50 ohms or 100 ohms.
NumaEn Non Uniform Memory Access (NUMA) is a distributed memory access mode. It allows reasonable memory allocation among multiple nodes and the processor to simultaneously access different memory addresses.
IsocEn Specifies whether to enable the isochronous flow-control mode, which ensures the quality of traffic to/from PCH and impacts the memory performance because some bandwidths are reserved for DMI.
RASMode Specifies the memory RAS mode. It can be independent mode, mirrored mode, or Lockstep mode.
enableSparing Rank Sparing setting switch
multiSparingRanks Haswell CPU supports multiple spare ranks. You can set the number of spare ranks for a channel.
spareErrTh Memory correctable error threshold. When the number of correctable errors reaches this threshold, an SMI will be triggered and measures will be taken based on the RAS feature configured.
PatrolScrub Controls the memory patrol scrub feature. The memory engine checks the memory at a certain speed and correct the correctable errors found, to prevent errors from being accumulated to uncorrectable errors.
PatrolScrubDuration Specifies the memory patrol duration in hours.
DemandScrubMode Controls the Demand Scrub feature. When HA reads memory data, it corrects errors found and writes correct data to the memory.
DeviceTaggingMode Controls the Device Tagging feature. This feature allows an SMI to be triggered when the number of errors occurred on a memory chip exceeds the threshold. During the SMI processing, a parity chip can be used to replace the faulty chip.
thermalthrottlingsupport Specifies the memory temperature adjustment mode.

Closed Loop Thermal Throttling (CLTT) applies to DIMMs with temperature sensors. It allows dynamic memory adjustment based on the sensor temperature.

Open Loop Thermal Throttling (OLTT) applies to DIMMs without temperature sensor. It allows static memory adjustment based on configuration.

PcieAcpiHotPlugEnable Specifies whether to enable IIO PCI-E Hotplug.
EnableAzaliaVCpOptimizationste Specifies whether to enable azalia_on_vcp.
PCIeSRIOVSupport Specifies whether to enable PCIe virtualization function.
VTdSupport Specifies whether to enable Intel VT for Directed I/O (VT-d).
InterruptRemap Specifies whether to enable Interrupt Remapping, which is related to VT-d.
CoherencySupport Specifies whether to enable Coherency Support, which is related to VT-d.
IsochCoherencySupport Specifies whether to enable Coherency Support (Isoch), which is related to VT-d.
IdeController Specifies whether to enable SATA controller.
SataCnfigure Specifies the SATA controller mode.
PchsSata Specifies whether to enable sSATA controller.
sSataInterfaceMode Specifies the sSATA controller mode.
XHCIMode Specifies the USB 3.0 controller switch.
CREnable Serial port redirection switch.
CRTerminalType Font type selection switch for serial port redirection.
CRBaudRate Baud Rate selection switch for serial port redirection.
CRInfoWaitTime Initialization information display time for serial port redirection.
CRAfterPost Specifies whether serial port redirection takes effect after BIOS POST.
PXE1setting LOM 1 PXE switch
PXE2setting LOM 2 PXE switch
WheaSupport Specifies whether to enable WHEA for fault diagnosis.
WheaEinjType Specifies whether to enable WHEA error injection for fault diagnosis.
SystemErrorEn Specifies whether to enable fault diagnosis.
FDM Specifies whether to enable reporting of fault diagnosis to the BMC.
PoisonEn Poison bit switch.
EMcaLogEn EMCA log (ELOG) switch. The BIOS creates ELOG entries, which record error information in detail for the OS/VMM to predict faults. The log is stored in the reserved memory provided by the BIOS and accessed through the Entry address. There is also a WHEA log corresponding to ELOG, and the structure of the WHEA log is defined by ACPI specifications.
EMcaCSmiEn CMCI-to-SMI signal switch.

If it is disabled, only CMCI will be triggered when correctable errors are found on the memory. An SMI will be triggered only when the number of errors reaches the threshold.

If it is enabled, each correctable error will trigger an SMI, which is processed by the BIOS. At the end of the SMI processing function, the BIOS decides whether to send an MCE signal to the OS. This helps to collect more useful information.

PowerStateRestoreOnACLoss Specifies the power control policy for the operating system when the AC is powered on.
  • ON: Automatic power-on
  • OFF: Remain power-off
  • Last State: Restore the last state
BmcWdtEnable Specifies whether to enable the POST watch dog.
BmcWdtTimeout Specifies the timeout period of the POST watch dog.
BmcWdtAction Specifies the POST watch dog actions.
OSWdtEnable Specifies whether to enable the OS watch dog.
OSWdtTimeout Specifies the timeout period of the OS watch dog.
OSWdtAction Specifies the OS watch dog actions.
SysDbgLevel BIOS debugging switch
serialDebugMsgLvl BISO debugging print level.
Pci64BitResourceAllocation If this function is enabled, the PCI MMIO address space is greater than 4 GB.
ClkGenSpreadSpectrum Spread spectrum switch.
WakeOnPME Wake On LAN switch.
NICTrunk Before OS starts, the DisableNic2ndhandle function will be called to disable the second optical port of 82599. This function is not available at present.
Language Specifies the language used.
ComBaseOutput Serial port IO base settings.
OemMemTurbo Memory overclock switch.
SoftRaidModeSelect SoftRAID selection switch.
BootType Specifies the boot type, which can be Legacy, UEFI, or DUAL.
QuickBoot Quick Boot settings. If it is disabled, a memory test will be performed after the first screen after each start.
QuietBoot Specifies whether to display boot information before the BIOS logo appears.
PXEOnly Specifies whether to limit the server to boot from PXE only and skip other boot options (such as a hard disk and CD-ROM).
VideoSelected Onboard video card or external video card
NoBootDevCtr Specifies whether the board is automatically restarted when no boot device is available.
BootTypeOrder[0] Specifies the boot sequence.
BootTypeOrder[1] Specifies the boot sequence.
BootTypeOrder[2] Specifies the boot sequence.
BootTypeOrder[3] Specifies the boot sequence.
Table 9-3  RAID controller card parameters
Type Export Parameter Export Subparameter Description Imported by Configuration File
Storage RaidController Type Specifies the controller type. Not supported

The value is displayed in the configuration file.

RaidController CopybackEnabled Specifies the copyback function status of the RAID controller card. Supported
RaidController SMARTerCopybackEnabled Specifies whether to automatically perform copyback when the RAID controller card detects a physical disk SMART error. Supported
RaidController JBODEnabled Specifies the JBOD function status of the RAID controller card. Supported