OSN 9800 V100 Configuration Guide 03

This document introduces service configuration process for OSN 9800.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring a VPLS Service

Configuring a VPLS Service

This topic describes how to configure a virtual private LAN service (VPLS).

Prerequisites

Procedure

  1. From the main menu of the U2000, choose Service > VPLS Service > Create VPLS Service. The Create VPLS Service window is displayed.

  2. In the Create VPLS Service window, set the basic attributes of the virtual private LAN service (VPLS).

  3. In Physical Topology on the right, double-click the NE one by one where the VPLS service needs to be configured and set Node Role of the NE to NPE.
  4. Click Details in the lower left corner of the window and click the PW Configuration tab. On the tab, select a tunnel that forwards a PW as follows: Select the PW and double-click the Forward Tunnel column and click . The Select Tunnel window is displayed.

    NOTE:

    Other parameters such as PWID, Forward Label, and Reverse Label can use the automatically assigned values or be specified based on the service plan.

    If you want to configure alarm-related data, select the ETH OAM CC check box in the lower left corner to enable the regular OAM CC function for the equipment.

  5. Select the tunnel and click OK.

    NOTE:

    Tunnels must be created between NEs that the created VPLS service traverses. If a tunnel that forwards PWs has not been created, click Create in the lower left corner of the Select Tunnel window. In the Create Tunnel window that is displayed, create the tunnel that forwards PWs. For details, see Configuring an MPLS Tunnel.

  6. Select the source NE, click SAI Configuration, then click SAI List, and click Create.

  7. In the displayed Create SAI window, select the board, port, and service VLAN mounted to NE, and click OK.
  8. Select the sink NE, and refer to 6 and 7 to select the board, port and service VLAN.
  9. Click OK or Apply to complete VPLS service configuration.

  10. In the Operation Result dialog box, click Browse Trail to view the VPLS service.

  11. Perform a loopback (LB) test to check the bidirectional connectivity of the VPLS service as follows: In the VPLS Service Management window, right-click the VPLS service and choose Ethernet OAM > LB Test.
  12. In the LB Test dialog box that is displayed, select the VPLS service and click Run.