OSN 9800 V100 Configuration Guide 03

This document introduces service configuration process for OSN 9800.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuration Process

Configuration Process

This topic describes the configuration process for an EoO board that receives and transmits data services.

Process of Service Configuration in E2E Mode

Figure 5-1 Configuration process in E2E mode

Table 5-1 describes the configuration steps.

Table 5-1 Configuration process
No. Step Description
1 Set the port type.

Mandatory

  • Set the port type to Ethernet Port of an EoO board.
  • Operation description: For details about the configuration procedure, see Setting the Port Type.
2 Set Ethernet interface attributes.

Mandatory

  • Set the Ethernet interface attributes of an EoO board.
  • Operation description: For details about the configuration procedure, see the Ethernet interface configuration process of Carry Ethernet service in Configuring an Ethernet Port.
NOTE:
On the network where a universal line board is used and data services are received on an EoO board, you do not need to configure virtual port mapping for the universal line board.
3 Configure service trails.

Mandatory

  • Configure the ODUk trails used by data services of the EoO board.
  • When you configure the source and sink ports of the trail, the port working mode must be set based on the actually used optical module.
  • Operation description: For details about the configuration method, see Creating ODUk Trails.
4 Configure data services for the EoO board.

Mandatory

  • Configure data services from the source NE to the sink NE on the EoO board.
  • Operation description: E-Line services that are transparently transmitted in point-to-point mode are used as an example. For details about the configuration method, see Process of Service Configuration in E2E Mode.