Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Operation Tasks of Configuring a CES Service

Operation Tasks of Configuring a CES Service

This topic describes the main operation tasks involved in configuring a CES service.

Configuring a CES Service Port

The OTN equipment can access CES services by using channelized STM-1 boards and channelized STM-4 boards, and provides flexible service access modes.

Prerequisites

You must be an NM user with "NE operator" authority or higher.

Context

The channelized STM-1 or STM-4 board is configured to transmit CES services, including VC4/VC12 CES emulation services.

When the interface is used to carry the CES service, you need to set the frame format, to ensure that the frame format is the same as the service encapsulation format.

NOTE:
The E1 frame mode of the PDH/SDH port packets of the PTN equipment support 30 and 31 timeslots.
  • 30 timeslots: The 1-15 and 17-31 timeslots in the E1 frame format are used to transmit service data. Timeslot 16 is used to transmit signaling.
  • 31 timeslots: The 1-31 timeslots in the E1 frame format are used to transmit service data.

When the Frame Mode of the packets on the opposite interface is set to 30, the Frame Mode of the packets on the local interface must be set to 30 to ensure that signaling in timeslot 16 of the user packet is transmitted as service data.

Modifying related parameters of created services may cause service interruption. Exercise caution when you perform this operation.

Tools, Equipment, and Materials

NMS

Legend Information

Figure 4-2 shows legend information about U2000 operations.
Figure 4-2 Legend Information

Port configuration procedure for a CES service(VC4)

  1. In the NE Explorer, select a channelized STM-1 or STM-4 board, and set Multiplex Type to VC4 and Link Protocol to TDM Encapsulation.
    NOTE:
    You are not advised to configure Multiplex Type for more than three ports at a time. Otherwise, a timeout error may occur after you click Apply.
    Operation Example:

Port configuration procedure for a CES service(VC12)

  1. In the NE Explorer, select a channelized STM-1 or STM-4 board and set Multiplex Type to VC12.

    Operation Example:

  2. On the Path Configuration tab, set port parameters such as VC12 Frame Format and Frame Mode.
    Operation Example:

    NOTE:

    When the emulation mode of a CES service is CESoPSN, E1 interface is recommended that you set the frame format at the interface to CRC-4 multiframe. When the emulation mode of a CES service is SAToP, the frame format at the interface should be set to non-framing.

  3. Select an object. In the Channel-sets area, click Create. In the Channel-sets [Create] window that is displayed, set Timeslot ID and Timeslot-list as planned.

    Operation Example:

Configuring Channel Overhead (VC-4/VC-12 Level)

For the channelized STM-1/STM-4 board, regenerator section overhead, VC-4 channel overhead, and VC-12 channel overhead can be configured.

Prerequisites

You must be an NM user with "NE operator" authority or higher.

Configuring a CES Service Port has been complete.

Tools, Equipment, and Materials

NMS

Legend Information

Figure 4-3 shows legend information about U2000 operations.
Figure 4-3 Legend Information

Configuring Regenerator Section Overhead

  1. In the NE Explorer, set Regenerator Section Overhead for the channelized STM-1 or STM-4 board.

    Operation Example:

Configuring VC4 Path Overhead

  1. In the NE Explorer, set J1 and C2 overhead bytes of VC4 Path Overhead for the channelized STM-1 or STM-4 board.
    • Operation Example: On the Trace Byte J1 tab, set the J1 overhead byte.

    • Operation Example: On the Signal Flag C2 tab, set the C2 overhead byte.

    • Operation Example: On the Overhead Termination tab, set the transparent transmission mode.

Configuring VC12 Path Overhead

  1. In the NE Explorer, set J2 and V5 overhead bytes of VC12 Path Overhead for the channelized STM-1 or STM-4 board.
    NOTE:
    When Channel Level displayed after you select Multiplex Type from the navigation tree is set to VC12, VC-12 channel overhead can be set.
    • Operation Example: On the Trace Byte J2 tab, set the J2 overhead byte.

    • Operation Example: On the Signal Flag V5 tab, set the V5 overhead byte.

Creating UNI-NNI CES Services in E2E Mode

This topic describes how to create UNI-NNI CES services in E2E mode.

Prerequisites

Tools, Equipment, and Materials

NMS

Procedure

  1. Choose Service > PWE3 Service > Create PWE3 Service from the main menu.
  2. In the Create PWE3 Service window, set the service type and service name.

  3. Click Configure Source and Sink and set the source and sink nodes.
    1. In the Configure Source and Sink dialog box that is displayed, set the board, service access port, and timeslot of the source node.

    2. Set a channel.

    3. Click Add Node.

    4. Set the sink node with reference to substeps 3.a, 3.b, and 3.c.
    5. Click OK.
  4. Specify the tunnel that forwards PWs. Select the desired PW that has been created, double-click the Forward Tunnel column and click . The Select Tunnel window is displayed. Specify the tunnel that forwards PWs and click OK.
  5. Click Detail. After confirming that service information is correct, click OK.
  6. In the Operation Result dialog box, click Browse Trail to view the newly created PWE3 service.
Translation