Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Verifying the Martini VPLS Configuration

Verifying the Martini VPLS Configuration

Prerequisites

All Martini VPLS configurations are complete.

Procedure

  • Run the display vsi [ name vsi-name ] [ verbose ] command to check information about a VPLS VSI.
  • Run the display l2vpn ccc-interface vc-type { all | vc-type } [ down | up ] command to check information about the interface used by an L2VPN connection.
  • Run the display vsi remote ldp [ [ router-id ip-address ] [ pw-id pw-id ] | verbose ] command to check information about a remote VSI.
  • Run the display vpls connection [ ldp | vsi vsi-name ] [ down | up ] [ verbose ] command to check information about a VPLS connection.
  • Run the display vpls forwarding-info [ vsi vsi-name [ peer peer-address [ negotiation-vc-id vc-id | remote-site site-id ] ] | state { up | down } ] [ verbose ] command to check forwarding information of all VSIs.
  • Run the display vsi services { all | vsi-name | interface interface-type interface-number | vlan vlan-id } command to check information about the AC interface associated with the VSI.
  • Run the display vsi pw out-interface [ vsi vsi-name ] command to check information about the outgoing interface of a PW in a VSI.
  • Run the display mpls label-stack vpls vsi vsi-name peer peer-ip-address vc-id vc-id command to check the information about label stacks in a VPLS scenario.