No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Smart Provisioning User Guide 09

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Overview

Overview

Smart Provisioning only supports V5 servers. You can press F6 during the BIOS startup process to enter the GUI of Smart Provisioning. For details about the startup process, see Logging In to Smart Provisioning. If you use Smart Provisioning by using the iBMC remote console, you are advised to download the iBMC remote console of the 1.0.5.228 version or later on the Support-E website. You can click on the login page of the iBMC remote console to query the version.

  • Smart Provisioning implements functions such as OS installation without a DVD, RAID configuration, and upgrade. Table 3-1 lists the functions.
  • Table 3-2 lists the servers supported by Smart Provisioning.
  • Smart Provisioning V108 or later supports secure startup. Two-socket V5 servers matching BIOS 0.65 or later or four-socket V5 servers matching BIOS 0.87 or later support secure startup of Smart Provisioning. Table 3-3 lists the OSs that can be installed in security mode.
  • Table 3-4 lists the mapping between Smart Provisioning and server BIOS versions.
  • Table 3-5 lists the devices that support firmware upgrade.
  • Smart Provisioning supports the iBMA installation only when the Windows/SUSE Linux Enterprise Server (SLES)/Red Hat Enterprise Linux (RHEL)/CentOS/Ubuntu16.04 LTS OSs are installed in silent mode.
Table 3-1 Functions

Function

Description

OS installation

Smart Provisioning supports OS installation in UEFI and Legacy modes. It supports mainstream OSs, including Windows, RHEL, CentOS, SLES, VMware and Ubuntu. Table 3-3 lists the supported OSs.

RAID configuration

Smart Provisioning supports the configuration of the Avago SAS3008, Avago SAS3108, Avago SAS3004, Avago SAS3408, Avago SAS3508, Avago SAS3416iMR, Avago SAS3516 RAID controller cards. The Avago SAS3416IT RAID controller cards can be queried.

Upgrade

  • PCIe devices include firmware of RAID controller cards and NICs (mainstream Huawei-developed cards and standard cards).
  • Hard disk (SAS and SATA) firmware
  • Smart Provisioning

Import and Export the Configuration

Supports import and export of the iBMC, BIOS, RAID controller card, and HBA configurations.

  • RAID controller cards include Avago SAS3004, LSI SAS3008IR, LSI SAS3108, Avago SAS3408, and Avago SAS3508. Scenarios where multiple RAID controller cards are used are not supported.
  • HBA cards include LPE 12002 and Qlogic 2672.
    NOTE:
    • Before importing the Qlogic 2672 configuration, ensure that the FC port of the card is properly connected to the storage device, and ensure that the ID of the imported TargetLUN node is the same as the host LUN ID configured in the LUN group on the storage device.
    • Before exporting the Qlogic 2672 configuration, ensure that the FC port of the card is properly connected to the storage device, and ensure that the remote boot information TargetWWPN configured for the port is the same as the WWPN of the connected storage device. Otherwise, the exported configuration information does not contain the target node.

Diagnose hardware

  • The function of obtaining hard disk slot information is supported only on servers using iBMC 2.53 or later.
  • The hard disk diagnosis function does not support scenarios where multiple RAID controller cards are used.
  • The hard disk diagnosis function supports the following hard disk vendors: Seagate, WDC, HGST, SanDisk, Toshiba, Intel, Micron, and Samsung.
  • The hard disk diagnosis function supports the following RAID controller card types: LSI SAS3008, LSI SAS3108, Avago SAS3408, Avago SAS3508, and PCH.

Collect logs

  • The function of obtaining hard disk slot information is supported only on servers using iBMC 2.53 or later.
  • The hard disk log collection function does not support scenarios where multiple RAID controller cards are used.
  • The hard disk log collection function supports the following hard disk vendors: HGST and Toshiba.
  • The hard disk log collection function supports the following RAID controller card types: LSI SAS3008, LSI SAS3108, Avago SAS3408, Avago SAS3508, and PCH.
Table 3-2 Supported servers

Type

Model

Rack server

5288 V5

2488 V5

2288 V5

2488H V5

5885H V5

1288H V5

2288H V5

8100 V5

High-density server

XH321 V5

XH321L V5

XH628 V5

Blade server

CH121L V5

CH121 V5

CH242 V5

CH221 V5

CH225 V5

Heterogeneous server

G530 V5

G560 V5

KunLun server

9008 V5

Table 3-3 Supported OSs

OS

Version

Whether Can Be Installed in Security Mode

Windows

Windows Server 2016 Standard (Desktop Experience)

Yes

Windows Server 2016 Standard

Yes

Windows Server 2016 Datacenter (Desktop Experience)

Yes

Windows Server 2016 Datacenter

Yes

Windows Server 2012 R2 Standard (Desktop Experience)

Yes

Windows Server 2012 R2 Standard

Yes

Windows Server 2012 R2 Datacenter (Desktop Experience)

Yes

Windows Server 2012 R2 Datacenter

Yes

RHEL

RHEL 7.6

No

RHEL 7.5

No

RHEL 7.4

No

RHEL 7.3

No

RHEL 6.9

No

RHEL 6.10

No

CentOS

CentOS 7.6

No

CentOS 7.5

No

CentOS 7.4

No

CentOS 7.3

No

CentOS 6.9

No

CentOS 6.10

No

SLES

SLES 12 SP3

No

SLES 12 SP2

No

SLES 11 SP4

No

VMware

VMware ESXi 6.5.0

Yes

VMware ESXi 6.5.0a

Yes

VMware ESXi 6.5.0d

Yes

VMware ESXi 6.5.0 Update 1

Yes

VMware ESXi 6.5.0 Update 2

Yes

VMware ESXi 6.0

No

VMware ESXi 6.7.0

Yes

Ubuntu

Ubuntu 16.04.2 LTS

No

Ubuntu 16.04.1 LTS

No

Ubuntu 16.04 LTS

No

Table 3-4 Server BIOS versions supporting Smart Provisioning startup

Server

BIOS Version Supporting Smart Provisioning Startup

2-socket V5 server, such as 2288H V5

0.38 or later

4-socket V5 rack server, such as 2488 V5 and 2488H V5

0.70 or later

5885/CH242 V5

0.69 or later

8100

0.73 or later

KunLun server

3.16 or later

High-density server, such as XH321 V5

0.38 or later

Atlas server, such as G530 V5

0.60 or later

Table 3-5 Devices supporting firmware upgrade

Device

Model

RAID controller card

3408IT

3516

3008IR

3008IT

3408iMR

3108

3508

3416IT

3416iMR

NIC

MZ520

QLE2672

X722

MCX4121A

SM211

SM212

SM231

SM233

SP330

SP332

Drive

AL14SEB030N and AL14SEB060N

HUC101830CSS200 and HUC101860CSS200

The drivers that can be automatically installed with the OS are listed in Table 3-6, Table 3-7, Table 3-8, Table 3-9, Table 3-10, and Table 3-11.

NOTE:

The boards or cards of the following OSs can be automatically installed during system deployment. Drivers of other boards or cards can be installed manually after iDriver that matches Smart Provisioning is downloaded from Huawei support (enterprise) or Huawei support (carrier).

Table 3-6 Drivers installed with Windows

OS Version

Board or Card Name

Driver Name

Windows Server 2016 Standard (Desktop Experience)/Windows Server 2016 Standard/Windows Server 2016 Datacenter (Desktop Experience)/Windows Server 2016 Datacenter

be3_net

NIC-BE3-Win2K16-11.4.1272.1-2_silence.exe or NIC-Lancer-Win2K16-11.4.327.0-5_silence.exe

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-BCM57810S-Win2k16-Qlogic-20.30.1.22-1.x86_64_silence.exe

QLE2690_2692

FC-QLEXXX-win2k16-qla2xxx-v9.2.9.23-x86_64_silence.exe

be3_iscsi

ISCSI-BE3-Win2K16-11.4.1205.0-11_silence.exe

3152_2100

RAID-3152_2100-win2k16-smartpqi-100.53.2.64.x86_64_silence.exe

be3_fcoe

FCOE-BE3-Win2K16-11.4.1220.0-14_silence.exe

lancer_fc&lancer_fc&lancer_fc

FC-Lancer-Win2k16-12.0.257.9-4_silence.exe

LSI3416iMR&LSI3408&LSI3508&LSI3516

RAID-Brcm-win2k16-megasas35-7.706.04.00-x86_64_silence.exe

LSI3416IT

3416IT_win2K16_x86_64_2.60.59.03_silence.exe

be3_fc&be3_fc&be3_fc&be3_fc

FC-LPFC-win2k16-lpfc-12.2.207.0-45-x86_64_silence.exe

LSI3004

3004iMR_win2k16_6.714.06.00_silence.exe

intel_i350&intel_x710_xl710&intel_82599&intel_x540&intel_x550&intel_x722

NIC-Intel-Win2K16-v23.5-x86_64_silence.exe

LSI3108

3108_win2k16_x86_64_6.712.13.00_silence.exe

Windows Server 2012 R2 Standard (Desktop Experience)/Windows Server 2012 R2 Standard/Windows Server 2012 R2 Datacenter (Desktop Experience)/Windows Server 2012 R2 Datacenter

be3_fc&be3_fc&be3_fc&be3_fc

FC-LPFC-win2k12r2-lpfc-12.2.207.0-45-x86_64_silence.exe

be3_fcoe

FCOE-BE3-Win2K12R2-11.4.1220.0-14_silence.exe

3152_2100

RAID-3152_2100-win2k12r2-smartpqi-100.53.2.64.x86_64_silence.exe

be3_iscsi

ISCSI-BE3-Win2K12R2-11.4.1205.0-11_silence.exe

LSI3008IR&LSI3008IT

3008_win2k12r2_x86_64_2.50.96.0_silence.exe

be3_net

NIC-Lancer-Win2K12R2-11.4.327.0-5_silence.exe or

NIC-BE3-Win2K12R2-11.4.1272.1-2_silence.exe

LSI3416iMR&LSI3408&LSI3508&LSI3516

RAID-Brcm-win2k12r2-megasas35-7.706.04.00-x86_64_silence.exe

LSI3416IT

3416IT_win2k12r2_x86_64_2.60.59.03_silence.exe

LSI3108

3108_win2k12r2_x86_64_6.712.13.00_silence.exe

LSI3004

3004iMR_win2k12r2_6.714.06.00_silence.exe

intel_i350&intel_x710_xl710&intel_82599&intel_x540&intel_x550&intel_x722

NIC-Intel-Win2K12R2-v23.5-x86_64_silence.exe

lancer_fc&lancer_fc&lancer_fc

FC-Lancer-Win2k12r2-12.0.257.9-4_silence.exe

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-BCM57810S-Win2k12R2-Qlogic-20.30.1.22-1.x86_64_silence.exe

QLE2690_2692

FC-QLEXXX-win2k12r2-qla2xxx-v9.2.9.23-x86_64_silence.exe

NOTE:

All the drivers listed in Table 3-6 will be automatically installed with the Windows OS. You can uninstall unnecessary drivers as required.

Table 3-7 Drivers installed with RHEL

OS Version

Board or Card Name

Driver Name

RHEL 7.6

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-RHEL7.6-megaraid_sas-07.706.07.00-1-x86_64.rpm

LSI3008IR&LSI3008IT&LSI3416IT&LSI3408IT

RAID-3008_3416IT-RHEL7.6-mpt3sas-27.00.00.00-1-x86_64.rpm

intel_x710_xl710&intel_x722

NIC-X722_X710_XL710-RHEL7.6-i40e-2.7.12-1-x86_64.rpm

intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-RHEL7.6-ixgbe-5.5.3-1-x86_64.rpm

intel_i350

NIC-I350-RHEL7.6-igb-5.3.5.20-1-x86_64.rpm

RHEL 7.5

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer_Rhel7.5-lpfc-12.0.261.8-1.x86_64.rpm

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-RHEL7.5-megaraid_sas-07.706.07.00-1-x86_64.rpm

lancer_net

NIC-Lancer-rhel7.5-lpnic-11.4.367.0-1.x86_64.rpm

be3_fcoe

FCoE-BE3-Rhel7.5-brcmfcoe-11.4.1272.0-1.x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-RHEL7.5-ixgbe-5.3.7-1-x86_64.rpm

be3_net

NIC-BE3-rhel7.5-be2net-11.4.1272.3-1.X86_64.rpm

intel_x710_xl710&intel_x722

NIC-X722_X710_XL710-RHEL7.5-i40e-2.7.12-1-x86_64.rpm

be3_iscsi

ISCSI-BE3-Rhel7.5-be2iscsi-11.4.1272.0-1.x86_64.rpm

LSI3008IR&LSI3008IT&LSI3416IT&LSI3408IT

RAID-3008_3416IT-RHEL7.5-mpt3sas-27.00.00.00-1-x86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-RHEL7.5-netxtreme2-7.14.48-1.x86_64.rpm

MZ731&MZ532

NIC-MZ532_MZ731-RHEL7.5-hinic-1.6.2.3-1.x86_64.rpm

RHEL 7.4

3152_2100

RAID-3152_2100-RHEL7.4-smartpqi-1.1.2-125-x86_64.rpm

be3_fcoe

FCoE-BE3-Rhel7.4-brcmfcoe-11.4.1272.0-1.x86_64.rpm

LSI3008IR&LSI3008IT&LSI3416IT&LSI3408IT

RAID-3008_3416IT-RHEL7.4-mpt3sas-24.00.00.00.x86-64.rpm

be3_iscsi

ISCSI-BE3-Rhel7.4-be2iscsi-11.4.1272.0-1.x86_64.rpm

lancer_net

NIC-Lancer-rhel7.4-lpnic-11.4.367.0-1.x86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-RHEL7.4-netxtreme2-7.14.48-1.x86_64.rpm

MZ731&MZ532

NIC-MZ532_MZ731-RHEL7.4-hinic-1.6.2.3-1.x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe:

FC&FCOE-Lancer-Rhel7.4-lpfc-12.0.261.8-1.x86_64.rpm

be3_net

NIC-BE3-rhel7.4-be2net-11.4.1272.3-1.X86_64.rpm

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-RHEL7.4-megaraid_sas-07.706.07.00-1-x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-RHEL7.4-ixgbe-5.3.7-1-x86_64.rpm

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-RHEL7.4-i40e-2.7.12-1.x86_64.rpm

RHEL 7.3

3152_2100

RAID-3152_2100-RHEL7.3-smartpqi-1.1.2-125-x86_64.rpm

3416IT&3408IT&LSI3008IR&LSI3008IT

RAID-3008_3416IT-RHEL7.3-mpt3sas-23.00.00.00-1-x86_64.rpm

be3_net

NIC-BE3-rhel7.3-be2net-11.4.1272.3-1.X86_64.rpm

intel_i350

NIC-I350-RHEL7.3-igb-5.3.5.20-1-x86_64.rpm

MZ731&MZ532

NIC-MZ532_MZ731-RHEL7.3-hinic-1.6.2.3-1.x86_64.rpm

be3_iscsi

ISCSI-BE3-Rhel7.3-be2iscsi-11.4.1272.0-1.x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer-Rhel7.3-lpfc-12.0.261.8-1.x86_64.rpm

lancer_net

NIC-Lancer-rhel7.3-lpnic-11.4.367.0-1.x86_64.rpm

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-RHEL7.3-megaraid_sas-07.706.07.00-1-x86_64.rpm

be3_fcoe

FCoE-BE3-Rhel7.3-brcmfcoe-11.4.1272.0-1.x86_64.rpm

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-RHEL7.3-i40e-2.7.12-1.x86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-RHEL7.3-netxtreme2-7.14.48-1.x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-RHEL7.3-ixgbe-5.3.7-1-x86_64.rpm

RHEL 6.9

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-RHEL6.9-megaraid_sas-07.706.07.00-1-x86_64.rpm

3152_2100

RAID-3152_2100-RHEL6.9-smartpqi-1.1.2-125-x86_64.rpm

lancer_net

NIC-Lancer-rhel6-lpnic-11.4.367.0-1.tar.gz

be3_iscsi

ISCSI-BE3-Rhel6-be2iscsi-11.4.1272.0-ds-1.tar.gz

intel_i350

NIC-I350-RHEL6.9-igb-5.3.5.20-1-x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer-Rhel6-lpfc-12.0.261.8-ds-1.tar.gz

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-RHEL6.9-netxtreme2-7.14.48-1.x86_64.rpm

be3_fcoe

FCoE-BE3-Rhel6-brcmfcoe-11.4.1272.0-ds-1.tar.gz

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-RHEL6.9-ixgbe-5.3.7-1-x86_64.rpm

3416IT&3408IT&LSI3008IR&LSI3008IT

RAID-3008_3416IT-RHEL6.9-mpt3sas-27.00.00.00-1-x86_64.rpm

be3_net

NIC-BE3-rhel6-be2net-11.4.1272.3-1.tar.gz

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-RHEL6.9-i40e-2.7.12-1.x86_64.rpm

RHEL 6.10

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-RHEL6.10-netxtreme2-7.14.48-1.x86_64.rpm

be3_fcoe

FCoE-BE3-Rhel6-brcmfcoe-11.4.1272.0-ds-1.tar.gz

be3_iscsi

ISCSI-BE3-Rhel6-be2iscsi-11.4.1272.0-ds-1.tar.gz

3416IT&3408IT&LSI3008IR&LSI3008IT

RAID-3008_3416IT-RHEL6.10-mpt3sas-28.00.00.00-1-x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer-Rhel6-lpfc-12.0.261.8-ds-1.tar.gz

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-RHEL6.10-ixgbe-5.3.7-1-x86_64.rpm

lancer_net

NIC-Lancer-rhel6-lpnic-11.4.367.0-1.tar.gz

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-RHEL6.10-i40e-2.7.12-1.x86_64.rpm

intel_i350

NIC-I350-RHEL6.10-igb-5.3.5.20-1-x86_64.rpm

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-RHEL6.10-megaraid_sas-07.706.07.00-1-x86_64.rpm

be3_net

NIC-BE3-rhel6-be2net-11.4.1272.3-1.tar.gz

Table 3-8 Drivers installed with CentOS

OS Version

Board or Card Name

Driver Name

CentOS 7.6

3408iMR&3416iMR&3508&3516&3004&LSI3108

RAID-Brcm-CentOS7.6-megaraid_sas-07.706.07.00-1-x86_64.rpm

LSI3008IR&LSI3008IT&3416IT&3408IT

RAID-3008_3416IT-CentOS7.6-mpt3sas-27.00.00.00-1-x86_64.rpm

intel_x710_xl710&intel_x722

NIC-X722_X710_XL710-CentOS7.6-i40e-2.7.12-1-x86_64.rpm

intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-CentOS7.6-ixgbe-5.5.3-1-x86_64.rpm

intel_i350

NIC-I350-CentOS7.6-igb-5.3.5.20-1-x86_64.rpm

CentOS 7.5

LSI3008IR&LSI3008IT&3416IT&3408IT

RAID-3008_3416IT-CentOS7.5-mpt3sas-27.00.00.00-1-x86_64.rpm

be3_iscsi

ISCSI-BE3-Centos7.5-be2iscsi-11.4.1272.0-1.x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-CentOS7.5-ixgbe-5.3.7-1-x86_64.rpm

3408iMR&3416iMR&3508&3516&3004&LSI3108

RAID-Brcm-CentOS7.5-megaraid_sas-07.706.07.00-1-x86_64.rpm

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-CentOS7.5-i40e-2.7.12-1-x86_64.rpm

be3_net

NIC-BE3-centos7.5-be2net-11.4.1272.3-1.X86_64.rpm

MZ731&MZ532

NIC-MZ532_MZ731-CentOS7.5-hinic-1.6.2.3-1.x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer_Centos7.5-lpfc-12.0.261.8-1.x86_64.rpm

be3_fcoe

FCoE-BE3-Centos7.5-brcmfcoe-11.4.1272.0-1.x86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-CentOS7.5-netxtreme2-7.14.48-1.x86_64.rpm

lancer_net

NIC-Lancer-centos7.5-lpnic-11.4.367.0-1.x86_64.rpm

CentOS 7.4

be3_iscsi

ISCSI-BE3-Centos7.4-be2iscsi-11.4.1272.0-1.x86_64.rpm

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-CentOS7.4-i40e-2.7.12-1.x86_64.rpm

3408iMR&3416iMR&3508&3516&3004&LSI3108

RAID-Brcm-CentOS7.4-megaraid_sas-07.706.07.00-1-x86_64.rpm

be3_net

NIC-BE3-centos7.4-be2net-11.4.1272.3-1.X86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-CentOS7.4-netxtreme2-7.14.48-1.x86_64.rpm

lancer_net

NIC-Lancer-centos7.4-lpnic-11.4.367.0-1.x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-CentOS7.4-ixgbe-5.3.7-1-x86_64.rpm

3152_2100

RAID_3152&2100_CentOS7.4_martpqi-1.1.2-125.x86_64.rpm

MZ731&MZ532

NIC-MZ532_MZ731-CentOS7.4-hinic-1.6.2.3-1.x86_64.rpm

be3_fcoe

FCoE-BE3-Centos7.4-brcmfcoe-11.4.1272.0-1.x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer-Centos7.4-lpfc-12.0.261.8-1.x86_64.rpm

LSI3008IR&LSI3008IT&3416IT&3408IT

RAID-3008_3416IT-CentOS7.4-mpt3sas-27.00.00.00-1-x86_64.rpm

CentOS 7.3

3152_2100

RAID_3152&2100_CentOS7.3_martpqi-1.1.2-125.x86_64.rpm

3408iMR&3416iMR&3508&3516&3004&LSI3108

RAID-Brcm-CentOS7.3-megaraid_sas-07.706.07.00-1-x86_64.rpm

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-CentOS7.3-i40e-2.7.12-1.x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer-Centos7.3-lpfc-12.0.261.8-1.x86_64.rpm

be3_net

NIC-BE3-centos7.3-be2net-11.4.1272.3-1.X86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-CentOS7.3-netxtreme2-7.14.48-1.x86_64.rpm

be3_iscsi

ISCSI-BE3-Centos7.3-be2iscsi-11.4.1272.0-1.x86_64.rpm

MZ731&MZ532

NIC-MZ532_MZ731-CentOS7.3-hinic-1.6.2.3-1.x86_64.rpm

intel_i350

NIC-I350-CentOS7.3-igb-5.3.5.20-1-x86_64.rpm

be3_fcoe

FCoE-BE3-Centos7.3-brcmfcoe-11.4.1272.0-1.x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-CentOS7.3-ixgbe-5.3.7-1-x86_64.rpm

lancer_net

NIC-Lancer-centos7.3-lpnic-11.4.367.0-1.x86_64.rpm

3416IT&3408IT&LSI3008IR&LSI3008IT

RAID-3008_3416IT-CentOS7.3-mpt3sas-28.00.00.00-1-x86_64.rpm

CentOS 6.9

lancer_net

NIC-Lancer-centos6-lpnic-11.4.367.0-1.tar.gz

be3_net

NIC-BE3-centos6-be2net-11.4.1272.3-1.tar.gz

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-CentOS6.9-megaraid_sas-07.706.07.00-1-x86_64.rpm

be3_iscsi

ISCSI-BE3-Centos6-be2iscsi-11.4.1272.0-ds-1.tar.gz

3416IT&3408IT&LSI3008IR&LSI3008IT

RAID-3008_3416IT-CentOS6.9-mpt3sas-27.00.00.00-1-x86_64.rpm

intel_i350

NIC-I350-CentOS6.9-igb-5.3.5.20-1-x86_64.rpm

3152_2100

RAID-3152_2100-CentOS6.9-martpqi-1.1.2-125-x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-CentOS6.9-ixgbe-5.3.7-1-x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer-Centos6-lpfc-12.0.261.8-ds-1.tar.gz

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-CentOS6.9-i40e-2.7.12-1.x86_64.rpm

be3_fcoe

FCoE-BE3-Centos6-brcmfcoe-11.4.1272.0-ds-1.tar.gz

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-CentOS6.9-netxtreme2-7.14.48-1.x86_64.rpm

CentOS 6.10

be3_iscsi

ISCSI-BE3-Centos6-be2iscsi-11.4.1272.0-ds-1.tar.gz

be3_net

NIC-BE3-centos6-be2net-11.4.1272.3-1.tar.gz

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-CentOS6.10-ixgbe-5.3.7-1-x86_64.rpm

lancer_net

NIC-Lancer-centos6-lpnic-11.4.367.0-1.tar.gz

3408iMR&3416iMR&3508&3516&3004&LSI3108

RAID-Brcm-CentOS6.10-megaraid_sas-07.706.07.00-1-x86_64.rpm

3416IT&3408IT&LSI3008IR&LSI3008IT

RAID-3008_3416IT-CentOS6.10-mpt3sas-27.00.00.00-1-x86_64.rpm

intel_i350

NIC-I350-CentOS6.10-igb-5.3.5.20-1-x86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-CentOS6.10-netxtreme2-7.14.48-1.x86_64.rpm

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-CentOS6.10-i40e-2.7.12-1.x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer-Centos6-lpfc-12.0.261.8-ds-1.tar.gz

be3_fcoe

FCoE-BE3-Centos6-brcmfcoe-11.4.1272.0-ds-1.tar.gz

Table 3-9 Drivers installed with SLES

OS Version

Board or Card Name

Driver Name

SLES 12 SP3

be3_iscsi

ISCSI-BE3-Sles12sp3-be2iscsi-11.4.1272.0.x86_64.rpm

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-SLES12SP3-i40e-2.7.12-1.x86_64.rpm

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-SLES12.3-megaraid_sas-07.706.07.00-1-x86_64.rpm

lancer_net

NIC-Lancer-sles12sp3-11.4.367.0-1.x86_64.rpm

be3_fcoe

FCOE-BE3-Sles12sp3-brcmfcoe-11.4.1272.0.x86_64.rpm

3416IT&3408IT&3008IR&3008IT

RAID-3008_3416IT-SLES12.3-mpt3sas-27.00.00.00-1-x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-SLES12SP3-ixgbe-5.3.7-1-x86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-SLES12.3-netxtreme2-7.14.48-1.x86_64.rpm

be3_net

NIC-BE3-sles12sp3-be2net-11.4.1272.3.x86_64.rpm

SLES 12 SP2

be3_iscsi

ISCSI-BE3-Sles12sp2-be2iscsi-11.4.1272.0.x86_64.rpm

3416IT&3408IT&3008IR&3008IT

RAID-3008_3416IT-SLES12.2-mpt3sas-27.00.00.00-1-x86_64.rpm

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-SLES12.2-megaraid_sas-07.706.07.00-1-x86_64.rpm

be3_fcoe

FCOE-BE3-Sles12sp2-brcmfcoe-11.4.1272.0.x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-SLES12SP2-ixgbe-5.3.7-1-x86_64.rpm

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-SLES12SP2-i40e-2.7.12-1.x86_64.rpm

be3_net

NIC-BE3-sles12sp2-be2net-11.4.1272.3.x86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-SLES12.2-netxtreme2-7.14.48-1.x86_64.rpm

lancer_net

NIC-Lancer-sles12sp2-lpnic-11.4.367.0-1.x86_64.rpm

3152_2100

RAID-3152_2100-SLES12.2-martpqi-1.1.2-125-x86_64.rpm

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer-Sles12sp-lpfc-12.0.261.8-ds-1.tar.gz

intel_i350

NIC-I350-SLES12SP2-igb-5.3.5.20-1-x86_64.rpm

SLES 11 SP4

3152_2100

RAID-3152_2100-SLES11.4-smartpqi-1.1.2-125-x86_64.rpm

intel_i350

NIC-I350-SLES11SP4-igb-5.3.5.20-1-x86_64.rpm

lancer_net

NIC-Lancer-sles11sp4-lpnic-11.4.367.0-1.x86_64.rpm

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-SLES11SP4-ixgbe-5.3.7-1-x86_64.rpm

be3_fcoe

FCOE-BE3-Sles11sp-brcmfcoe-11.4.1272.0-ds-1.tar.gz

lancer_fc&lancer_fc&lancer_fc&lancer_fcoe&lancer_fcoe

FC&FCOE-Lancer-Sles11sp4-lpfc-12.0.261.8.x86_64.rpm

be3_net

NIC-BE3-sles11sp4-be2net-11.4.1272.3.x86_64.rpm

intel_x710_xl710&intel_x722&intel_x722&intel_x722&intel_x722

NIC-X722_X710_XL710-SLES11SP4-i40e-2.7.12-1.x86_64.rpm

3408iMR&3416iMR&3508&3516&3004&3108

RAID-Brcm-SLES11.4-megaraid_sas-07.706.07.00-1-x86_64.rpm

3416IT&3408IT&3008IR&3008IT

RAID-3008_3416IT-SLES11.4-mpt3sas-27.00.00.00-1-x86_64.rpm

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-MZ520_MZ522-SLES11.4-netxtreme2-7.14.48-1.x86_64.rpm

be3_iscsi

ISCSI-BE3-Sles11sp-be2iscsi-11.4.1272.0-ds-1.tar.gz

Table 3-10 Drivers installed with VMware ESXi

OS Version

Board or Card Name

Driver Name

ESXi 6.7

be3_fc&be3_fc&be3_fc&be3_fc

FC-Emulex-ESXi6.7-lpfc-12.0.257.5-1.x86_64.zip

ConnectX-4_sp333&ConnectX-4_sm380&ConnectX-4_sp380

NIC-SP380-SM380-SP333-ESXi6.7-mlx5_core-4.17.14.2-x86_64.zip

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-ESXi6.7-ixgbe-4.4.1-x86_64.zip

3416IT

RAID-3416IT-ESXi6.7-lsi_msgpt35-4.00.00.00-x86_64.zip

lancer_lpnic

NIC-Lancer-ESXi6.7-lpnic-11.4.385.0.x86_64.zip

3152_2100

RAID-3152_2100-ESXi6.7-smartpqi-1.0.2.1038-x86_64.zip

lancer_lpfc&lancer_lpfc&lancer_lpfc&lancer_fcoe&lancer_fcoe&lancer_fcoe

FC_FCOE-Lancer-ESXi6.7-lpfc-12.0.257.5-1.x86_64.zip

LSI3008IR

RAID-3008-ESXi6.7-lsi_msgpt3-16.00.00.00-x86_64.zip

intel_X722&intel_X722&intel_X722&intel_X722&intel_X710_XL710

NIC-X710_XL710_X722-ESXi6.7-i40en-1.7.11-1.x86_64.zip

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-BCM57810S-ESXi6.7-bnx2-60.713.76-1.x86_64.zip

3408iMR&3416iMR&3508&3516&3004&LSI3108

RAID-Brcm-ESXi6.7-lsi_mr3-7.706.09.00-1-x86_64.zip

BCM5719&BCM5720

NIC-5719_5720-ESXi6.7-tg3-3.136h-x86_64.zip

QLE2XXX&QLE2XXX&QLE2XXX

FC-QLEXXX-ESXi6.7-qla2xxx-v3.1.16.0-x86_64.zip

ESXi 6.5

intel_X722&intel_X722&intel_X722&intel_X722&intel_X710_XL710

NIC-X710_XL710_X722-ESXi6.5-i40en-1.7.11-1-x86_64.zip

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-BCM57810S-ESXi6.5-bnx2-60.713.76-1.x86_64.zip

be3_iscsi

ISCSI-BE3-ESXi6.5-elxiscsi-11.4.1210.0-1.x86_64.zip

intel_82599&intel_82599&intel_82599&intel_x540

NIC-X540_X550_82599-ESXi6.5-ixgbe-4.4.1-x86_64.zip

3408iMR&3416iMR&3508&3516&3004&LSI3108

RAID-Brcm-ESXi6.5-lsi_mr3-7.706.09.00-1-x86_64.zip

be3_fc&be3_fc&be3_fc&be3_fc

FC-Emulex-ESXi6.5-lpfc-12.0.257.5-1.x86_64.zip

3152_2100

RAID-3152_2100-ESXi6.5.0-smartpqi-1.0.1.256-x86_64.zip

lancer_lpfc&lancer_lpfc&lancer_lpfc&lancer_fcoe&lancer_fcoe&lancer_fcoe

FC_FCOE-Lancer-ESXi6.5-lpfc-12.0.257.5-1.x86_64.zip

QLE2XXX&QLE2XXX&QLE2XXX

FC-QLEXXX-ESXi6.5-qla2xxx-2.1.81.0-x86_64.zip

be3_net

NIC-MZ510_MZ512-ESXi6.5-elxnet-11.4.1272.2-1.x86_64.zip

lancer_lpnic

NIC-Lancer-ESXi6.5-lpnic-11.4.385.0.x86_64.zip

BCM5719&BCM5720

NIC-5719_5720-ESXi6.5-tg3-3.136h-x86_64.zip

be3_fcoe

FCOE-BE3-ESXI6.5-brcmfcoe-11.4.1266.0-1.x86_64.zip

ConnectX-4_sp333&ConnectX-4_sm380&ConnectX-4_sp380

NIC-SM380_SP380-SP333-ESXi6.5-mlx5_core-4.16.14.2-x86_64.zip

LSI3008IR

RAID-3008-ESXi6.5-lsi_msgpt3-16.00.00.00-x86_64.zip

3416IT

RAID-3416IT-ESXi6.5-lsi_msgpt35-4.00.00.00-1-x86_64.zip

ESXi 6.0

3152_2100

RAID-3152_2100-ESXi6.0-smartpqi-1.0.1.256-x86_64.zip

intel_82599&intel_82599&intel_x540&intel_x550

NIC-X540_X550_82599-ESXi6.0-ixgbe-4.4.1-x86_64.zip

be3_iscsi

ISCSI-BE3-ESXi6.0-be2iscsi-11.4.1210.0-1.zip

3416IT

RAID-3416IT-ESXi6.0-lsi_msgpt35-4.00.00.00-1-x86_64.zip

BCM5719&BCM5720

NIC-5719_5720-ESXi6.0-tg3-3.136h-x86_64.zip

ConnectX-4_sp333

NIC-SP333-ESXi6.0-mlx5_core-4.15.10.3-1-x86_64.zip

QLE2XXX&QLE2XXX&QLE2XXX

FC-QLEXXX-ESXi6.0-qla2xxx-v2.1.81.0-1-x86_64.zip

be3_fc&be3_fc&be3_fc&be3_fc

FC-Emulex-ESXi6.0-lpfc-12.0.193.14-1.x86_64.zip

BCM57810S&BCM57810S&BCM57810S&BCM57810S

CNA-BCM57810S-ESXi6.0-bnx2-60.713.76-1.x86_64.zip

3408iMR&3416iMR&3508&3516&3004&LSI3108

RAID-Brcm-ESXi6.0-lsi_mr3-7.706.09.00-1-x86_64.zip

lancer_lpnic

NIC-Lancer-ESXi6.0-lpnic-11.4.385.0.x86_64.zip

intel_X722&intel_X722&intel_X722&intel_X722

NIC-X722-ESXi6.0-i40en-1.7.11-1-x86_64.zip

LSI3008IR

RAID-3008-ESXi6.0-lsi_msgpt3-16.00.00.00-x86_64.zip

lancer_lpfc&lancer_lpfc&lancer_lpfc&lancer_fcoe&lancer_fcoe&lancer_fcoe

FC_FCOE-Lancer-ESXi6.0-lpfc-12.0.257.5-1.x86_64.zip

intel_i350&intel_i350&intel_82580&intel_82580

NIC-I350_82580-ESXi6.0-igb-5.2.10-x86_64.zip

be3_fcoe

FCOE-BE3-ESXi6.0-brcmfcoe-11.4.1266.0-1.x86_64.zip

be3_net

NIC-MZ510_MZ512-ESXi6.0-elxnet-11.4.1272.2-1.x86_64.zip

Table 3-11 Drivers installed with Ubuntu

OS Version

Board or Card Name

Driver Name

Ubuntu 16.04.2 LTS

LSI3008IR&LSI3008IT&3416IT&3408IT

RAID-3008_3416IT-Ubuntu16.04.2-mpt3sas-23.00.00.00-1-x86_64.deb

3408iMR&3416iMR&3508&3516&LSI3108&3004

RAID-Brcm-Ubuntu16.04.2-megaraid_sas-07.706.07.00-1-x86_64.deb

3152_2100

RAID-3152_2100-Ubuntu16.04.2-martpqi-1.1.2-125-x86_64.deb

SLES12SP3_64

Ubuntu 16.04.1 LTS

3152_2100

RAID-3152_2100-Ubuntu16.04.1-martpqi-1.1.2-125-x86_64.deb

3408iMR&3416iMR&3508&3516&LSI3108&3004

RAID-Brcm-Ubuntu16.04.1-megaraid_sas-07.706.07.00-1-x86_64.deb

Ubuntu 16.04 LTS

3408iMR&3416iMR&3508&3516&3004&LSI3108

RAID-Brcm-Ubuntu16.04-megaraid_sas-07.703.09.00-1-x86_64.deb

3152_2100

RAID-3152_2100-Ubuntu16.04-martpqi-1.1.2-125-x86_64.deb

3416IT&3408IT&LSI3008IR&LSI3008IT

RAID-3008_3416IT-Ubuntu16.04-mpt3sas-27.00.00.00-1-x86_64.deb

Table 3-12 lists the mapping relationships between OSs and RAID controller card types.

Table 3-12 Mapping relationships between OSs and RAID controller card types

OS

LSI SAS3008

LSI SAS3108

Avago SAS3408

Avago SAS3408IT

Avago SAS3508

Avago SAS3004

Avago SAS3416iMR

Avago SAS3416IT

Avago SAS3516

AHCI

Windows Server 2016 Standard (Desktop Experience)/Windows Server 2016 Standard/Windows Server 2016 Datacenter (Desktop Experience)/Windows Server 2016 Datacenter

×

Windows Server 2012 R2 Standard (Desktop Experience)/Windows Server 2012 R2 Standard/Windows Server 2012 R2 Datacenter (Desktop Experience)/Windows Server 2012 R2 Datacenter

×

RHEL 7.6

RHEL 7.5

RHEL 7.4

RHEL 7.3

RHEL 6.10

RHEL 6.9

CentOS 7.6

CentOS 7.5

CentOS 7.4

CentOS 7.3

CentOS 6.10

CentOS 6.9

SLES 12 SP3

SLES 12 SP2

SLES 11 SP4

VMware ESXi 6.5.0

×

VMware ESXi 6.5.0a

×

VMware ESXi 6.5.0d

×

VMware ESXi 6.5.0 Update 1

×

VMware ESXi 6.5.0 Update 2

×

VMware ESXi 6.0

×

VMware ESXi 6.7.0

Only the LSI SAS3008IR is supported.

×

×

×

×

×

×

Ubuntu 16.04.2 LTS

×

×

×

×

×

Ubuntu 16.04.1 LTS

×

×

×

×

×

Ubuntu 16.04 LTS

NOTE:

Note 1: Only UEFI mode is supported.

Table 3-13 lists the OSs that can be deployed on different storage media.

Table 3-13 Storage medium compatibility list

OS

SANBoot

USB Storage Medium

NVMe Pass-through Mode

NVMe VMD Mode

Windows Server 2016 Standard (Desktop Experience)/Windows Server 2016 Standard/Windows Server 2016 Datacenter (Desktop Experience)/Windows Server 2016 Datacenter

×

×

Windows Server 2012 R2 Standard (Desktop Experience)/Windows Server 2012 R2 Standard/Windows Server 2012 R2 Datacenter (Desktop Experience)/Windows Server 2012 R2 Datacenter

×

×

RHEL 7.6

×

RHEL 7.5

×

RHEL 7.4

×

RHEL 7.3

×

×

RHEL 6.10

×

×

×

×

RHEL 6.9

×

×

×

CentOS 7.6

×

CentOS 7.5

×

CentOS 7.4

×

CentOS 7.3

×

×

CentOS 6.9

×

×

×

CentOS 6.10

×

×

×

×

SLES 12 SP3

×

SLES 12 SP2

×

×

SLES 11 SP4

×

×

×

VMware ESXi 6.5.0

×

VMware ESXi 6.5.0a

×

VMware ESXi 6.5.0d

×

VMware ESXi 6.5.0 Update 1

×

VMware ESXi 6.5.0 Update 2

×

VMware ESXi 6.0

×

VMware ESXi 6.7.0

×

Ubuntu 16.04.2 LTS

×

×

Ubuntu 16.04.1 LTS

×

×

×

Ubuntu 16.04 LTS

×

×

×

NOTE:
  • Currently, only the LPe16002 and MZ520 SANBoot deployment modes are supported.
  • Currently, the USB storage medium supports only Huawei USB-SD adapters. Other USB storage media such as USB flash drives and USB removable hard disks are not supported.
  • All the preceding systems do not support Legacyboot deployment in NVMe pass-through mode or VMD mode.
  • When the system is deployed on an NVMe disk, the Avago 3004 RAID controller card cannot be configured or PCH pass-through hard disks cannot be installed. If other RAID controller cards are configured, hard disks cannot be installed. Otherwise, the system will be deployed on a hard disk.
Translation
Download
Updated: 2019-05-11

Document ID: EDOC1100034052

Views: 27064

Downloads: 342

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next