Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking Whether Smart Provisioning Is Installed on the V5 Server

Checking Whether Smart Provisioning Is Installed on the V5 Server

Scenario

Before using Smart Provisioning, check whether Smart Provisioning is loaded to the V5 server. You can use uREST tool to query the Smart Provisioning information to check whether Smart Provisioning is successfully loaded.

For details about how to use uREST tool, see uREST tool 2.0 User Guide. To view or obtain the latest document, log in to the Support-E website, choose Support > Documentation > Servers > Server Management Software > FusionSever Tools > Operation & Maintenance > User Guide.

Prerequisites

  • uREST tool is installed.
  • The server type is V5.

Procedure

  1. Run the following command to query Smart Provisioning information:

    ./urest -H HOST -p PORT -U USERNAME -P PASSWORD getspinfo

    Table 2-1 describes the parameters.

    Table 2-1 Parameter description

    Parameter

    Description

    Value

    HOST

    Specifies the IPv4/IPv6 address or domain name of the iBMC on the server. This parameter is mandatory. If an IPv6 address is used, the IPv6 address must be enclosed in parentheses, for example, [1001::1001].

    -

    PORT

    Specifies the port number. The default value is 443. This parameter is optional.

    If the actual port number is not 443, enter the actual port number.

    USERNAME

    Specifies the user name of the iBMC administrator. This parameter is mandatory.

    -

    PASSWORD

    Specifies the password of the iBMC administrator. This parameter is mandatory.

    -

    Information similar to the following is disllayed:

    [root@localhost bin]# ./urest -H 10.10.10.10 -U ****** -P ****** getspinfo 
    SysRestartDelaySeconds        : 30 
    SPStartEnabled                : False 
    
    [Version] 
    OSVersion                     : 1.** 
    APPVersion                    : 1.** 
    DataVersion                   : 1.**
    Table 2-2 describes the output items.
    Table 2-2 Output description

    Output Item

    Description

    SysRestartDelaySeconds

    Specifies the system restart delay. The unit is second.

    SPStartEnabled

    Specifies whether to enable or disable the Smart Provisioning service.

    • True: The service is enabled.
    • False: The service is disabled.

    OSVersion

    Specifies the Smart Provisioning system version.

    APPVersion

    Specifies the Smart Provisioning application version.

    DataVersion

    Specifies the Smart Provisioning data version.

  2. Check whether Smart Provisioning is installed on the server.