No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LSPV_1.3.6.1.4.1.2011.5.25.302.3.2 hwLspTraceProbe

LSPV_1.3.6.1.4.1.2011.5.25.302.3.2 hwLspTraceProbe

Description

LSPV/4/LSPTRACEPROBE: OID [oid] The trap of LSP trace test.(hwLspTunnelID=[INTEGER], hwLspSenderAddress=[INTEGER], hwLspEndPointAddress=[INTEGER], hwLspTTL=[INTEGER], hwLspHandle=[INTEGER])

The device sent an LSP trace test trap to notify the NMS of the LSP trace packet received.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.302.3.2 Warning communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

hwLspTunnelID

ID of the LSP tunnel

hwLspSenderAddress

Source address of the LSP trace packet

hwLspEndPointAddress

Destination address of the LSP trace packet

hwLspTTL

TTL value of the LSP trace packet

hwLspHandle

Handle value of the LSP trace packet

Impact on the System

The system will not be affected.

Possible Causes

An LSP trace packet was sent to check the link connectivity.

Procedure

  1. The alarm is informational only, and no action is required.

Related Information

None.