Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
POE 1.3.6.1.4.1.2011.5.25.195.40.26 hwPoePSEPowerCut

POE 1.3.6.1.4.1.2011.5.25.195.40.26 hwPoePSEPowerCut

Description

POE/4/PSEPOWERCUT: OID [oid] PSE power is not enough to power on all the PD.Some low priority PD may power off.

The maximum output power of the PoE power supply is lower than the total power required by all the PDs connected to the PSE. As a result, the PSE may fail to supply power to some low-priority PDs.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.195.40.26 Warning environmentalAlarm (6)

Parameters

Name Meaning
OID

Indicates the MIB object ID of the alarm.

Impact on the System

Some low-priority PDs may be powered off.

Possible Causes

The maximum output power of the PoE power supply is insufficient.

Procedure

  1. Run the display poe-power command to check the maximum PoE power.

    • If the maximum PoE power is smaller than the total power required by the PDs but cannot be increased, run the poe priority { critical | high | low } command to set power supply priorities for PDs. Then low-priority PDs are powered off and power supply of high-priority PDs is ensured.

Related Information

None.