No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136196

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136196

Description

ENTITYTRAP/4/OPTICALINVALID: OID [oid] Optical module is invalid.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=136196, EntityTrapReasonDescr="Input Optical Power Too Low")

The optical module does not work normally because the receive power of the optical module was too low.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.4.5 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid

Indicates the MIB object ID of the alarm.

Index Indicates the index.
EntityPhysicalIndex Indicates the index of the physical entity.
PhysicalName Indicates the name of the physical entity.
EntityTrapFaultID Indicates the error code.
EntityTrapReasonDescr Indicates the description of the error code.

Impact on the System

The services on the corresponding interface will be interrupted.

Possible Causes

The receive power of the optical module was too low.

Procedure

  1. Run the display interface command in the user view to check whether the receive power Rx Power of the optical module is within the allowed range. If so, collect alarms, logs, and configurations, and contact technical support personnel.
  2. If no alarm on low receive power is generated and the peer interface is Up, go to step 5.
  3. If the peer interface is Down and an alarm on that is generated, rectify the peer interface.
  4. Check whether the optical fiber is faulty. If so, replace the optical fiber.
  5. Replace the local optical module.
  6. If the fault persists after the optical module and fiber are replaced, collect alarms, logs, and configurations, and contact technical support personnel.
Translation
Download
Updated: 2019-08-12

Document ID: EDOC1100034065

Views: 142888

Downloads: 42

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next