No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ISIS_1.3.6.1.4.1.2011.5.25.24.2.4.6 hwIsisL1ImportRouteThresholdReach

ISIS_1.3.6.1.4.1.2011.5.25.24.2.4.6 hwIsisL1ImportRouteThresholdReach

Description

ISIS/4/L1_REDIST_THRESHOLD_REACH:OID [oid] The number of level-1 imported routes has reached the upper threshold value.(sysInstance=[integer], sysProtocol=[integer], sysMTIndex=[integer], sysMaxLimit=[integer], sysUpperThresholdValue=[integer], sysLowerThresholdValue=[integer], sysTotalRedist=[integer])

The number of external routes imported to an IS-IS Level-1 area reached the configured upper threshold for advertising routes.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.24.2.4.6

Warning

equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

sysInstance

ID of an IS-IS process

sysProtocol

Protocol types
  • 1: IPv4
  • 2: IPv4

sysMTIndex

Multi-topology ID

sysMaxLimit

Maximum number of imported routes that are allowed to be advertised

sysUpperThresholdValue

Alarm upper threshold

sysLowerThresholdValue

Alarm lower threshold

sysTotalRedist

Number of imported routes

Impact on the System

Some of the imported routes cannot be advertised.

Possible Causes

The number of imported routes reached the configured threshold.

Procedure

  1. Run the display current-configuration command to view limitations on the number of routes that can be imported.

    • If the configured threshold is small, run the import-route limit command to change the threshold to a proper value.

    • If the configured threshold is proper, go to Step 2.

  2. Check whether the routes are correctly imported in the IS-IS process. If external routes are imported incorrectly, run the undo import-route command in the IS-IS view to delete the routes that are imported incorrectly. Then check whether the alarm is cleared.

    • If the alarm persists, go to Step 3.

    • If the alarm is cleared, go to Step 4.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.