Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
WLAN_1.3.6.1.4.1.2011.6.139.16.1.1.1.9 hwStaInterfDetectedTrap

WLAN_1.3.6.1.4.1.2011.6.139.16.1.1.1.9 hwStaInterfDetectedTrap

Description

WLAN/4/STATION_DISTURB: OID [oid] Jam of station is detected notify.(APMAC=[OPAQUE], RadioID=[INTEGER], ApName=[OCTET], APID=[INTEGER])

STA interference was detected.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.6.139.16.1.1.1.9 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid Indicates the ID of the MIB object.
APMAC Indicates the MAC address of an AP.
RadioID Indicates the radio ID.
ApName Indicates the AP name.
APID Indicates the AP ID.

Impact on the System

If the number of interfering STAs exceeds the alarm threshold, the AP service performance is degraded.

Possible Causes

The number of interfering STAs exceeded the alarm threshold.

Procedure

  1. Run the display radio-2g-profile { all | name profile-name } and display radio-5g-profile { all | name profile-name } commands to view the value of Station interference threshold and check whether the alarm threshold for STA interference is configured properly. It is recommended that you set the alarm threshold for STA interference to 32.

    • If so, go to Step 3.
    • If not, go to Step 2.

  2. Run the interference station threshold command to set a proper alarm threshold for STA interference. Then, check whether the alarm persists.

    • If so, go to Step 3.
    • If not, go to Step 5.

  3. Keep the AP away from the STAs that cause interference to decrease the STA interference to be lower than the alarm threshold. Then, check whether the alarm persists.

    • If so, go to Step 4.
    • If not, go to Step 5.

  4. Collect alarm messages, log messages, and configurations, and then contact the technical support personnel.
  5. End.

Related Information

None.