This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
GRE_1.3.6.1.4.1.2011.5.25.201.3.2_hwOverflowTunnelTimeoutOverThreshold

GRE_1.3.6.1.4.1.2011.5.25.201.3.2_hwOverflowTunnelTimeoutOverThreshold

Description

GRE/4/OVERFLOW_TUNNEL_TIMEOUT:OID [oid] The number of expired overflow tunnels reached the threshold in a period. (TunnelType=[TunnelType], KeepaliveTimeoutPeriod =[KeepaliveTimeoutPeriod], KeepaliveTimeoutThreshold =[KeepaliveTimeoutThreshold], TunnelTimeOutCnt=[TunnelTimeOutCnt])

The times that the local end fails to send a Keepalive packet to the peer end through the Overflow tunnel exceeded the alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.201.3.2 Warning other

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

TunnelType

Tunnel type

KeepaliveTimeoutPeriod

Period

KeepaliveTimeoutThreshold

Maximum number of retry times

TunnelTimeOutCnt

Times that the local end fails to send a Keepalive packet to the peer end

Impact on the System

Services will not be affected.

Possible Causes

Cause:

The times that the local end fails to send a Keepalive packet to the peer end through the Overflow tunnel exceeded the alarm threshold. By default, an alarm is generated if the local end fails to send a Keepalive packet to the peer end for 100 times within 15 minutes.

Procedure

  • This log message is informational only, and no action is required.