No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PSECHIPINVALID

PSECHIPINVALID

Description

HUAWEI POE/PSECHIPINVALID: PSE chip fault for some reason! (ChipIndex=[integer])

The PoE chip is faulty.

Attribute

Alarm ID Alarm Severity Alarm Type
None None None

Parameters

Name Meaning
ChipIndex Indicates the chip ID.

Impact on the System

The device cannot provide power for PDs.

Possible Causes

The PoE chip or IIC channel is faulty, causing the CPU unable to access the PoE chip.

Procedure

  • Run the reboot command to restart the device. If the fault persists, replace the device.

Related Information

Translation
Download
Updated: 2019-05-07

Document ID: EDOC1100034065

Views: 132622

Downloads: 40

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next