Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FIB_1.3.6.1.4.1.2011.5.25.227.2.1.3 hwBoardFwdResLack

FIB_1.3.6.1.4.1.2011.5.25.227.2.1.3 hwBoardFwdResLack

Description

FIB/2/BOARD_FWD_RES_LACK:OID [oid] The board forwarding engine resources were overloaded. (EntPhysicalindex=[INTEGER], EntPhysicalName=[OCTET], Reason=[INTEGER])

The board forwarding engine resources were overloaded.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.227.2.1.3 Major qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

EntPhysicalindex

Index of the physical entry

EntPhysicalName

Name of the physical entry

Reason

Probable cause for the trap, which can only be:
  • 94: The number of forward tokens on the board.

Impact on the System

The board forwarding engine resources are overloaded, and certain services may be interrupted.

Possible Causes

Cause 94:

The number of forward tokens on the board exceeded the specifications of the forwarding engine resources.

Procedure

  1. Run the display mpls lsp statistics command to check whether the number of created tunnels exceeds the expected number and whether the number of tokens on the device exceeds the maximum value.

    • If the number of created tunnels exceeds the expected number, remove the redundant tunnels. If the alarm persists, go to Step 2.

    • If the number of created tunnels does not exceed the expected number, go to Step 2.

  2. Collect alarm information and configuration information, and then contact technical support personnel.