No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.5 hwBoardInvalid 132614

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.5 hwBoardInvalid 132614

Description

ENTITYTRAP/4/BOARDINVALID: OID [oid] Board is invalid for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=132614, EntityTrapReasonDescr="EPLD Logic Faulty")

The board fails.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.2.5 Warning equipmentAlarm(5)

Parameters

Name Meaning
OID

Indicates the MIB object ID of the alarm.

Index Indicates the entity index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the name of the physical entity.
EntityTrapEntType Indicates the type of the physical entity, such as mpu(1), and lpu(2).
EntityTrapFaultID Indicates the error code.
EntityTrapReasonDescr Indicates the description of the error code.

Impact on the System

Services will be interrupted.

Possible Causes

The EPLD logic was faulty.

Procedure

  1. Check whether the faulty board is registered successfully and services are running properly.

    Run the display device command to check whether the faulty board is registered successfully, and run the display interface counters command to view the statistics on received and sent packets. According to the statistics, check whether services are running properly.

    • If the faulty board is registered successfully and services are running properly, no action is required.
    • If the faulty board is unregistered or services are not running properly, go to step 2.

  2. If the faulty board is a main control board, run the reboot command to reboot the device. If the faulty board is an interface board, run the reset slot command to reset the faulty interface board. Then check whether the device is working properly.

    • If the board can be registered successfully and services are running properly, no action is required.
    • If the board cannot be registered or services cannot run properly, the board hardware is faulty. Replace this board.
    • If the fault persists, go to step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
Translation
Download
Updated: 2019-08-12

Document ID: EDOC1100034065

Views: 152692

Downloads: 42

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next