Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
WLAN_1.3.6.1.4.1.2011.6.139.16.1.1.1.19 hwRadioPowerChangedTrap

WLAN_1.3.6.1.4.1.2011.6.139.16.1.1.1.19 hwRadioPowerChangedTrap

Description

WLAN/4/RADIO_POWER_CHANGE_NOTIFY:OID [oid] Power of radio is changed.(APMAC=[OPAQUE], RadioID=[INTEGER], APName=[OCTET], ACTUAL POWER=[INTEGER], APID=[INTEGER])

The alarm is generated when the AP radio power was changed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.6.139.16.1.1.1.19 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the ID of the MIB object.
APMAC Indicates the MAC address of an AP.
RadioID Indicates the radio ID of the AP.
APName Indicates the AP name.
ACTUAL POWER Indicates the actual power.
APID Indicates the AP ID.

Impact on the System

None.

Possible Causes

1:

A notification about the power configuration modification was sent to the AP.

2:

The global calibration was enabled.

3:

The local calibration was enabled.

4:

The periodic calibration was enabled.

Procedure

  1. No action is required.

Related Information

None.