Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PIM_1.3.6.1.4.1.2011.5.25.149.4.0.17 hwPimSGThresholdExceed

PIM_1.3.6.1.4.1.2011.5.25.149.4.0.17 hwPimSGThresholdExceed

Description

PIM/3/hwPimSGThresholdExceed:OID [oid] PIM (S, G) entries of all instances count reached the upper threshold. (hwPimNotificationAddressType=[integer], hwPimSGCurrentCount=[integer], hwPimSGThreshold=[integer]%, hwPimSGTotalCount=[integer])

The proportion of global PIM (S, G) entries created to the maximum global PIM (S, G) entries allowed reached the upper alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.149.4.0.17

Minor

communicationsAlarm

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

hwPimNotificationAddressType

Group address type:
  • 1: IPv4 address

  • 2: IPv6 address

hwPimSGCurrentCount

Number of global PIM (S, G) entries created

hwPimSGThreshold

Alarm threshold for global PIM (S, G) entries

hwPimSGTotalCount

Maximum number of global PIM (S, G) entries allowed

Impact on the System

If the number of (S, G) PIM entries in the system reaches the upper limit and this alarm is reported, the device cannot create new PIM entries, causing failures to forward some multicast traffic.

Possible Causes

The proportion of global PIM (S, G) entries created to the maximum global PIM (S, G) entries allowed reached the upper alarm threshold.

Procedure

  1. Check whether the upper alarm threshold is too low in the configuration file.

    • If the threshold is too low, go to Step 2.

    • If the threshold is not low, go to Step 3.

  2. Run the pim source-group-number threshold-alarm upper-limit upper-limit-value lower-limit lower-limit-value command in the multicast MIB view to set the upper alarm threshold to a larger value.
  3. Confirm whether network expansion is required. If network expansion is required, contact technical support personnel.
  4. End.

Related Information