Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.32 hwDot1agCfmUnexpectedMEGLevel

EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.32 hwDot1agCfmUnexpectedMEGLevel

Description

EOAM1AG/1/UNEXPECTEDMEGLEVEL: OID [oid] MEP received a CCM with unexpected MEG level. (MdIndex=[GAUGE], MaIndex=[GAUGE], MdName=[STRING], MaName=[STRING], MepId=[INTEGER])

The MD level carried in a CCM sent by the RMEP was different from that specified on the MEP.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.136.1.6.32 Critical communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

MdIndex

Index of an MD table

MaIndex

Index of an MA table

MdName

Name of an MD

MaName

Name of an MA

MepId

ID of a MEP

Impact on the System

CFM will fail.

Possible Causes

The MD level carried in a CCM sent by the RMEP was different from that specified on the MEP.

Procedure

  1. Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command on both the MEP and RMEP to view the value of the Level field. Check whether the MD levels are the same.

    • If the MD levels are different, go to Step 2.

    • If the MD levels are the same, go to Step 3.

  2. Perform the following steps on the MEP:
    1. Run the undo cfm md name md-name command to delete existing MD configurations.
    2. Run the cfm md md-name level level command to reconfigure an MD the same as that on the RMEP.
    3. Run the display alarm active command to view the trap. Check whether the trap is cleared. If the trap persists, go to Step 3.
  3. Collect alarm information and configuration information, and then contact technical support personnel.