Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
POE_1.3.6.1.4.1.2011.5.25.195.40.2 hwPoePowerOff

POE_1.3.6.1.4.1.2011.5.25.195.40.2 hwPoePowerOff

Description

POE/4/POWEROFF: OID [oid] PD powered off.(IfIndex=[INTEGER], Interface="[OCTET]")

The PD connected to the specified interface is powered off.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.195.40.2 Warning communicationsAlarm(2)

Parameters

Name Meaning
OID

Indicates the MIB object ID of the alarm.

IfIndex Indicates the interface index.
Interface Indicates the interface name.

Impact on the System

The PD connected to the specified interface is powered off.

Possible Causes

1:

The PD was removed.

2:

The PD was faulty.

3:

The power was insufficient, so the interface with a higher priority preempts the power.

4:

The interface was automatically powered off in the power-off time range.

Procedure

  1. Check whether the PD is removed.

    • If so, go to step 2.
    • If not, go to step 3.

  2. Install the PD and check whether the alarm is cleared.

    • If so, go to step 11.
    • If not, go to step 3.

  3. Check whether the power is sufficient.

    • If so, go to step 7.
    • If not, go to step 4.

  4. Check whether the priority of this interface is low.

    • If so, go to step 5.
    • If not, go to step 8.

  5. Check whether the interface priority needs to be reset.

    • If so, use the poe priority command to reset the interface priority.
    • If not, increase the PoE power.

  6. Check whether the alarm is cleared.

    • If so, go to step 11.
    • If not, go to step 6.

  7. Check whether the PD is faulty.

    • If so, go to step 8.
    • If not, go to step 9.

  8. Replace the PD and go to step 11.
  9. Check whether the interface is in the power-off time range.

    • If so, go to step 11.
    • If not, go to step 8.

  10. Collect alarm information and configuration information, and then contact technical support personnel.
  11. End.