Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm Message Format Description

Alarm Message Format Description

Format of Alarm Message

The alarm message begins with "#". Figure 3-1 shows the output format of an alarm message.

Figure 3-1  Output format of an alarm message

Fields

Field

Description

#

Information type: # indicates the alarm information.

TimeStamp

It is the time when an alarm message is generated. It is a variable of the date type and expressed in the format Mmm dd yyyy hh:mm:ss.

  • Mmm indicates a month. It can be Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nov, or Dec.
  • dd indicates a date of a month. If the value is less than 10, it is expressed as "(blank)date". For example, " 7".
  • yyyy indicates a year.
  • hh:mm:ss indicates the local time. hh ranges from 00 to 23. mm or ss ranges from 00 to 59.

TimeStamp and HostName are separated by a space.

HostName

It is the system name of a local host. The default HostName is Huawei.

HostName and ModuleName are separated by a space.

ModuleName

It specifies the module that generates alarm messages. ModuleName and Severity are separated by a slash (/).

Severity

Alarm messages are classified into six severity levels.

Severity and Brief are separated by a slash (/).

Brief

It is a phrase that summarizes information.

There should be a colon (:) between the Brief field and the Description field.

Description

It is a string of characters that describe a detailed alarm message. It is output by a module to the information center. It is filled in by a module at each output time.