Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NQA_1.3.6.1.4.1.2011.5.25.111.6.28 nqaResultsTestResultChange

NQA_1.3.6.1.4.1.2011.5.25.111.6.28 nqaResultsTestResultChange

Description

NQA/4/TESTRESULTCHANGE:OID [oid] NQA entry test result changed. (OwnerIndex=[OCTET], TestName=[OCTET], ResultsIndex=[INTEGER], ResultsHop=[INTEGER], LastRecentResult=[INTEGER], CurrentResult=[INTEGER])

ICMP test results changed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.111.6.28 Warning environmentalAlarm(5)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
OwnerIndex Manager of the NQA test instance
TestName Name of the NQA test instance
ResultsIndex Index of the NQA test result table
ResultsHop Hop table index of the NQA test instance
LastRecentResult Last-time NQA test results
CurrentResult Current NQA test results

Impact on the System

The system will not be affected.

Possible Causes

ICMP test results changed.

Procedure

  1. If the status of a test instance changes from succeeded to failed, check whether the link has been interrupted.
  2. Collect alarm information and configuration information, and then contact technical support personnel.
  3. End.