Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RMON_1.3.6.1.4.1.2011.1.3.4.0.1 pririsingAlarm

RMON_1.3.6.1.4.1.2011.1.3.4.0.1 pririsingAlarm

Description

RMON/1/RISING:OID [OID] Private alarm table [alarm-line-index] monitors [description] with sample type [sample-type], has sampled alarm value [alarm-value] uprise [alarm-upper-limit].

The value of the alarm entity was higher than prialarmRisingThreshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.1.3.4.0.1 Minor communicationsAlarm(2)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

alarm-line-index

Indicates the index of the alarm entry.

description

Indicates the description of the alarm entry

sample-type

Indicates the type of the sampled alarm.

alarm-value

Indicates the alarm value.

alarm-upper-limit

Indicates the upper threshold of the alarm.

Impact on the System

None.

Possible Causes

Cause 1:

If the current sampled value was greater than or equal to this threshold, and the last sampled value was less than this threshold, the alarm was generated.

Cause 2:

When this alarm entry became valid, the first sampled value was greater than or equal to this threshold, and prialarmStartupAlarm was equal to risingAlarm and risingOrFallingAlarm, the alarm was generated.

Procedure

  • This alarm is triggered only when the upper alarm monitoring threshold configured using the rmon prialarm command is reached. It is a user-configured monitoring alarm and does not affect services. Therefore, no action is required.

Related Information

None.