Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PDOVERLOAD

PDOVERLOAD

Description

HUAWEI POE/PDOVERLOAD: PD on the port is over load.(PortIndex=[integer])

The power of the PD connected to the specified port increases sharply, causing insufficient power supply on the port.

Attribute

Alarm ID Alarm Severity Alarm Type
None None None

Parameters

Name Meaning
None None

Impact on the System

Insufficient power supply on the port may cause low-priority PDs to be automatically powered off.

Possible Causes

The power of the PD connected to the port increases sharply.

Procedure

  1. Run the display poe power port { port-num | all } command to check the maximum power configured for the specified port.
  2. Run the display poe-power command to check the total power of PDs connected to all ports.
  3. Perform the following steps as required:

    • If the maximum output power configured for the port is smaller than the total power required by the PDs and can be increased, run the poe power port port-num port-power-max command to increase the maximum output power. Ensure that the output power is sufficient for all the PDs.

    • If the maximum output power configured for the port is smaller than the total power required by the PDs but cannot be increased, run the poe priority { critical | high | low } port port-num command to set power supply priorities for PDs. Then low-priority PDs are powered off and power supply of high-priority PDs is ensured.