Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.9 hwSysSlaveSwitchFailNotification

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.9 hwSysSlaveSwitchFailNotification

Description

SYSMIB/3/SWITCH_FAIL:OID [oid] Slave switchover fail.

An active/standby switchover failed.

NOTE:

Only AR3200 series supports this alarm.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.9 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid

Indicates the MIB object ID of the alarm.

Impact on the System

Services are not affected.

Possible Causes

1. No standby main control unit is available.

2. The standby main control unit has failed.

3. The active/standby switchover function is not enabled.

4. An error has occurred during the active/standby switchover.

Procedure

  1. Run the display device command to check whether the standby main control unit is available.

    • If no standby main control unit is available, install the standby main control unit and go to step 4.

    • If the standby main control unit is available, go to step 2.

  2. Run the display current-configuration command to check whether the active/standby switchover function is enabled.

    • If the active/standby switchover function is not enabled, run the switchover enable command to enable this function and go to step 4.

    • If the active/standby switchover function is enabled, go to step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.

Related Information

None

Translation