Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136201

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136201

Description

ENTITYTRAP/4/OPTICALINVALID:OID [oid] Optical module is invalid.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=136201, EntityTrapReasonDescr="Optical Temperature Too High")

The temperature of the optical module exceeds the upper limit.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.4.5 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid

Indicates the MIB object ID of the alarm.

Index Indicates the index of the alarm.
EntityPhysicalIndex Indicates the entity index.
PhysicalName Indicates the name of the physical entity.
EntityTrapFaultID Indicates the error code of the alarm.
EntityTrapReasonDescr Indicates the description of the error code.

Impact on the System

Services are interrupted on the interface with the optical module installed.

Possible Causes

The temperature of the optical module exceeds the upper limit.

Procedure

  1. Run the display transceiver verbose command in user view to check temperature of the optical module.
  2. If temperature of the optical module exceeds the upper limit, improve the ventilation and heat dissipation of the device to lower the temperature.
  3. If the alarm persists, collect alarm information, log information, and configuration of the device and contact technical support personnel.
Translation