Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FWDTRAP_1.3.6.1.4.1.2011.5.25.227.2.1.36 hwFwdSessionResLack

FWDTRAP_1.3.6.1.4.1.2011.5.25.227.2.1.36 hwFwdSessionResLack

Description

FWDTRAP/2/SESSIONRESLACK:OID [oid] The device session resources were overloaded.(Usage = [INTEGER]%)

The number of forwarding flow tables on the device reaches or exceeds 90% or 100% of the maximum number, an alarm is generated.
NOTE:

If the number of forwarding flow tables changes too rapidly within a short period of time, multiple alarms may be generated. As a result, the system records these alarms, affecting normal services on the device. To prevent the device from recording a large number of alarms, the system suppresses the alarms by setting the interval at which alarms are sent to longer than 30 minutes. That is, the system records an alarm at least 30 minutes after the last alarm was cleared.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.227.2.1.36 Major equipmentAlarm(5)

Parameters

Name Meaning
[oid]

Indicates the MIB object ID of the alarm.

Usage

The proportion that the number of forwarding flow tables on the device accounts for of the maximum number.

Impact on the System

Services are affected.

Possible Causes

The number of forwarding flow tables on the device reaches or exceeds 90% or 100% of the maximum number.

Procedure

  • Check service configurations and contact technical support personnel.