Alarm Handling

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.38 hwDot1agCfmUnexpectedPeriod

EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.38 hwDot1agCfmUnexpectedPeriod

Description

EOAM1AG/3/UNEXPECTEDPERIOD: OID [oid] MEP received a CCM with unexpected period. (MdIndex=[GAUGE], MaIndex=[GAUGE], MdName=[STRING], MaName=[STRING], MepId=[INTEGER], RmepId=[INTEGER])

The CCM interval carried in a CCM sent by the RMEP was different from that specified on the MEP.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.136.1.6.38 Minor communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

MdIndex

Index of an MD table

MaIndex

Index of an MA table

MdName

Name of an MD

MaName

Name of an MA

MepId

ID of a MEP

RmepId

ID of an RMEP

Impact on the System

CFM will fail.

Possible Causes

The CCM interval carried in a CCM sent by the RMEP was different from that specified on the MEP in the scenario where the MEP and RMEP had the same MD level and MA ID, and the MEP was enabled to receive CCMs carrying the specified RMEP ID.

Procedure

  1. Run the display cfm ma [ md md-name [ ma ma-name ] ] command to view the value of the Interval field on the MEP and RMEP. Check whether the intervals configured on the MEP and RMEP are the same.

    • If they are the same, go to Step 3.

    • If they are different, go to Step 2.

  2. Perform the following steps on the MEP:
    1. Run the cfm md md-name command to enter the MD view.
    2. Run the display this command. Check whether the mep ccm-send enable command has been run to enable the MEP to send CCMs and the remote-mep ccm-receive enable command has been run to enable the MEP to receive CCMs.
    3. If the mep ccm-send enable command has been run, run the undo mep ccm-send enable command to disable the MEP from sending CCMs.
    4. If the remote-mep ccm-receive enable command has been run, run the undo remote-mep ccm-receive enable command to disable the MEP from receiving CCMs.
    5. Run the ccm-interval interval command to configure the interval between CCMs the same as the interval configured on the RMEP. Then run the remote-mep ccm-receive enable command to enable the MEP to receive CCMs and the mep ccm-send enable command to enable the MEP to send CCMs.
    6. Run the mep ccm-send enable command to enable the MEP to send CCMs.
    7. Run the remote-mep ccm-receive enable command to enable the MEP to receive CCMs.
    8. Run the display alarm active command to view the trap. Check whether the trap is cleared. If the trap persists, go to Step 3.
  3. Collect alarm information and configuration information, and then contact technical support personnel.