Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HWCM_1.3.6.1.4.1.2011.6.10.2.9 hwConfigInconsistent

HWCM_1.3.6.1.4.1.2011.6.10.2.9 hwConfigInconsistent

Description

HWCM/2/CONFIG_DIFF:OID [oid] The configurations on the master and slave main control boards were inconsistent.

The trap was generated when the configurations for the master and slave main control boards were inconsistent.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.6.10.2.9 Major equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

Impact on the System

If a master/slave switchover is performed, services may become abnormal.

Possible Causes

Configurations for the master and slave main control boards were inconsistent.

Procedure

  1. Run the display current-configuration [ configuration [ configuration-type [ configuration-instance ] ] | controller [ interface-type [ interface-number ] ] | interface [ interface-type [ interface-number ] ] ] [ feature feature-name [ filter filter-expression ] | filter filter-expression ] command on the master main control board to display the current configurations and then save them locally.
  2. Log in to the slave main control board. Then, run the display current-configuration [ configuration [ configuration-type [ configuration-instance ] ] | controller [ interface-type [ interface-number ] ] | interface [ interface-type [ interface-number ] ] ] [ feature feature-name [ filter filter-expression ] | filter filter-expression ] command on the slave main control board to display the current configurations and then save them locally.
  3. Check whether the locally saved configurations for the master and slave main control boards in 1 and 2 are consistent.

    • If the configurations are inconsistent, go to 4.
    • If the configurations are consistent, go to 5.

  4. Collect alarm information and configuration information, and then contact technical support personnel.
  5. End.

Related Information

None