Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Maintaining the Fast Provisioning Function

Maintaining the Fast Provisioning Function

The configuration information learned by a sub-interface can be cleared so that the sub-interface can relearn relevant configurations automatically.

Context

Configuration information about the fast provisioning function can be automatically loaded to a device to be configured using the USB-based deployment method. After a sub-interface on the device to be configured automatically learns the configuration information, you can clear the configuration information learned by the sub-interface if the configuration information is different from the planned configuration. The sub-interface then can relearn the configuration information.

NOTE:

After the fast provisioning function is enabled, the device starts a timer since the first time the automatic learning function is triggered. The fast provisioning function is automatically disabled globally and on interfaces 1 hour later. If the device restarts within 1 hour, the fast provisioning function will not be automatically disabled 1 hour later. In this case, the fast provisioning function can only be disabled using the undo fast provisioning enable command.

After a sub-interface finishes automatic learning of configuration information, the automatic learning record is not deleted when configuration on the sub-interface changes. To trigger automatic learning on the sub-interface again, run the reset fast-provisioning command on the main interface of the sub-interface to clear configurations on all sub-interfaces of the main interface.

If multiple sub-interfaces of a main interface have finished automatic learning and one of them needs to learn configuration again, run the reset fast-provisioning command on the main interface to clear configurations on all the sub-interfaces. The sub-interfaces can then automatically learn the configuration again.

If a new sub-interface is created on a main interface after all the previous sub-interfaces of the main interface finish automatic learning of configurations, run the reset fast-provisioning command on the main interface to clear configurations of all the sub-interfaces. Then all the sub-interfaces can automatically learn configurations again.

Procedure

  • In the interface view, run the reset fast-provisioning command to clear the configuration learned and saved by a specified interface using the fast provisioning function. The sub-interface then can relearn the configuration information.

    NOTE:
    • In the main interface view, run the reset fast-provisioning command to clear all the configuration information saved by sub-interfaces of the main interface.

    • In the sub-interface view, run the reset fast-provisioning command to clear only the IP address saved by the sub-interface.