No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CLI-based Configuration Guide - Reliability

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides guidance for configuring reliability services, including interface backup, BFD, VRRP, and EFM.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Single-ended SLM in a VLAN

Configuring Single-ended SLM in a VLAN

To perform packet loss performance measurement on the point-to-multipoint or multipoint-to-multipoint link, deploy single-ended SLM to monitor the link quality.

Context

VLAN-based single-ended SLM can be implemented in on-demand or proactive mode. On-demand single-ended SLM is initiated manually and calculates the frame loss at a time or periodically during diagnosis. Proactive single-ended SLM calculates the frame loss continuously.
  • To count single-ended packet loss performance of a link at a time or periodically, configure on-demand single-ended SLM.

  • To count single-ended packet loss performance of a link continuously, configure proactive single-ended SLM.

Procedure

  1. Perform basic CFM configurations on the MEP and RMEP.

    1. Run system-view

      The system view is displayed.

    2. Run vlan vlan-id

      A VLAN is created and the VLAN view is displayed.

      By default, all interfaces belong to the default VLAN, that is, VLAN 1.

    3. Run port interface-type { interface-number1 [ to interface-number2 ] } &<1-10>

      The default VLAN is configured for an interface and the interface is added to the default VLAN.

      By default, VLAN 1 is the default VLAN of all interfaces.

    4. Run cfm enable (system view)

      CFM is enabled globally.

      By default, CFM is disabled globally.

    5. Run cfm md md-name

      The MD view is displayed.

    6. Run ma ma-name

      The MA view is displayed.

    7. Run map vlan vlan-id

      The MA is bound to a VLAN.

      By default, an MA is not associated with any VLAN.

    8. Run mep mep-id mep-id interface interface-type interface-number [ vlan vlan-id | pe-vid pe-vid ce-vid ce-vid ] { inward | outward }

      A MEP is configured.

    9. Run mep ccm-send [ mep-id mep-id ] enable

      The MEP is enabled to send CCMs.

      By default, a MEP is disabled from sending CCMs.

    10. Run remote-mep mep-id mep-id [ mac mac-address ]

      The RMEP is configured.

      NOTE:

      When this command is configured on the transmit device, the mac mac-address command must be configured. Otherwise, on-demand single-ended SLM cannot be configured, and proactive single-ended SLM can be configured but does not take effect.

    11. Run remote-mep ccm-receive [ mep-id mep-id ] enable

      The MEP is enabled to receive CCMs from the RMEP.

      By default, a MEP is disabled from receiving CCMs from an RMEP.

    12. Run test-id test-id mep mep-id remote-mep mep-id [ 8021p 8021p-value ] [ description description ]

      A test instance is configured.

      By default, no test instance is configured in an MA.

    NOTE:
    • The MEP ID on the transmit device must be the same as the RMEP ID on the receive device.
    • The RMEP ID on the transmit device must be the same as the MEP ID on the receive device.

  2. On the receive device enabled with single-ended SLM, run: loss-measure single-ended-synthetic receive test-id test-id [ time-out timeout-value ]

    The RMEP is enabled to receive SLM frames.

    By default, the REMP is not enabled to receive SLM frames in an MA.

  3. Configure single-ended SLM on the transmit device enabled with single-ended SLM.

    • Configure on-demand single-ended SLM.

      Run loss-measure single-ended-synthetic send test-id test-id interval { 10 |100 | 1000 | 10000 } [ sending-count count-value ] [ time-out time-out-value ] [ packet-size packet-size ] [ measurement-count measurement-count ]

      On-demand single-ended SLM is configured.

      By default, on-demand single-ended SLM is not configured in an MA.

    • Configure proactive single-ended SLM.

      Run loss-measure single-ended-synthetic continual send test-id test-id interval { 10 | 100 | 1000 | 10000 } [ sending-count count-value ] [ time-out timeout ] [ packet-size packet-size ]

      Proactive single-ended SLM is configured.

      By default, proactive single-ended SLM is not configured in an MA.