No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CLI-based Configuration Guide - Reliability

AR100, AR120, AR150, AR160, AR200, AR1200, AR2200, AR3200, and AR3600 V200R010

This document provides guidance for configuring reliability services, including interface backup, BFD, VRRP, and EFM.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Interface Backup in Active/Standby Mode

Configuring Interface Backup in Active/Standby Mode

Pre-Configuration Tasks

Before configuring interface backup in active/standby mode, configure routing protocols on the primary link and backup link to ensure connectivity at the network layer.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The primary interface view is displayed.

  3. Run standby interface interface-type interface-number [ priority ]

    A backup interface is specified and the priority of the backup interface is set. To configure multiple backup interfaces for a primary interface, run the standby interface command multiple times.

  4. (Optional) Run standby timer delay enable-delay disable-delay

    The switchover delay is set. When the values of enable-delay and disable-delay are 0, services are switched immediately. It is recommended that the switchover delay should not be 0 because immediate switching may cause link flapping.

    NOTE:

    To prevent frequent switchovers between the primary interface and the backup interface because of the unstable interface status, run the standby timer delay command to set the delay. After the primary interface changes from Up to Down, the system does not switch services to the backup interface immediately:

    • If the primary interface is still Down after the delay, services are switched to the backup interface.

    • If the primary interface is restored during the delay, services are not switched.

Checking the Configuration

After the configuration is complete, please run the display standby state command to check the status of the primary and backup interfaces.